Design Buy Build Issue 18 2016 | Page 80

° Domestic and residential high pressure water mist fire suppression system Standard Features             Technical Features Domestic & residential Multi-room coverage Up to 10 ceiling mounted nozzles, supplied by 1 pump 57° heat activated frangible bulb Flexible high pressure hose installation No water storage tank required No dedicated water supply required Runs straight from mains water supply with a standard 22mm water inlet UK manufacturer Maintenance contracts Full design service at no additional cost Full survey and specification service at no additional cost        Single phase 230V supply Volt free connection as standard Alarm connectivity AOV connectivity PLC controlled Audible alarm feature on activation or fault as standard Nozzles designed to fit standard GU10 Light-fitting Nozzle – Ceiling Mounted DD8458 – 1:2010 compliant system is the trade mark of Mist Fire Suppression Ltd HPWM systems for Greater London and the South West of England London office: 0207 167 6560 Bude office: 01288 355787 Email: [email protected] Web: www.mistfs.co.uk Manufacturers and installers of [Type here] Mist Fire Suppression Ltd