DBV Product Technical Guide Fall 2021 | Seite 75

DBV Rainscreen Facade Product Technical Guide
R-VALUE TABLES
Fox HT Concrete 5 " ( 127mm )
Brackets : Horizontal thermally broken brackets ( medium size ) Base Material : Concrete 5 " ( 127mm )
Vertical Bracket to Bracket Spacing 24 " Vertical ( 609.6mm ) 30 " Vertical ( 762mm ) 36 " Vertical ( 914.4mm ) 42 " Vertical ( 1066.8mm ) 48 " Vertical ( 1219.2mm )
Horizontal Stud to Stud Spacing
Exterior Insulation Thickness * in . ( cm )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
0.38 pcs / ft ² ( bracket ) 4.04 pcs / m ² ( bracket )
0.3 pcs / ft ² ( bracket ) 3.28 pcs / m ² ( bracket )
0.26 pcs / ft ² ( bracket ) 2.78 pcs / m ² ( bracket )
0.23 pcs / ft ² ( bracket ) 2.52 pcs / m ² ( bracket )
0.21 pcs / ft ² ( bracket ) 2.28 pcs / m ² ( bracket )
0.75 ft / ft ² ( rails ) 2.46 m / m ² ( rails )
16 " ( 406.4mm )
4 ( 10.2 )
0.056 ( 0.32 )
17.735 ( 3.122 )
0.056 ( 0.318 )
17.849 ( 3.142 )
0.056 ( 0.317 )
17.925 ( 3.156 )
0.056 ( 0.316 )
17.966 ( 3.163 )
0.056 ( 0.316 )
18.002 ( 3.169 )
5 ( 12.7 )
0.045 ( 0.256 )
22.174 ( 3.904 )
0.045 ( 0.255 )
22.266 ( 3.92 )
0.045 ( 0.254 )
22.328 ( 3.931 )
0.045 ( 0.254 )
22.36 ( 3.937 )
0.045 ( 0.254 )
22.389 ( 3.942 )
6 ( 15.2 )
0.038 ( 0.217 )
26.17 ( 4.607 )
0.038 ( 0.216 )
26.326 ( 4.635 )
0.038 ( 0.215 )
26.431 ( 4.653 )
0.038 ( 0.214 )
26.486 ( 4.663 )
0.038 ( 0.214 )
26.535 ( 4.672 )
0.25 pcs / ft ² ( bracket ) 2.69 pcs / m ² ( bracket )
0.2 pcs / ft ² ( bracket ) 2.19 pcs / m ² ( bracket )
0.17 pcs / ft ² ( bracket ) 1.85 pcs / m ² ( bracket )
0.16 pcs / ft ² ( bracket ) 1.68 pcs / m ² ( bracket )
0.14 pcs / ft ² ( bracket ) 1.52 pcs / m ² ( bracket )
0.5 ft / ft ² ( rails ) 1.64 m / m ² ( rails )
24 " ( 609.6mm )
4 ( 10.2 )
0.055 ( 0.314 )
18.074 ( 3.182 )
0.055 ( 0.313 )
18.153 ( 3.196 )
0.055 ( 0.312 )
18.206 ( 3.205 )
0.055 ( 0.312 )
18.233 ( 3.21 )
0.055 ( 0.311 )
18.258 ( 3.214 )
5 ( 12.7 )
0.045 ( 0.253 )
22.455 ( 3.953 )
0.044 ( 0.252 )
22.517 ( 3.964 )
0.044 ( 0.252 )
22.559 ( 3.972 )
0.044 ( 0.252 )
22.581 ( 3.976 )
0.044 ( 0.251 )
22.601 ( 3.979 )
6 ( 15.2 )
0.038 ( 0.214 )
26.53 ( 4.671 )
0.038 ( 0.213 )
26.636 ( 4.69 )
0.037 ( 0.213 )
26.708 ( 4.702 )
0.037 ( 0.212 )
26.745 ( 4.709 )
0.037 ( 0.212 )
26.779 ( 4.715 )
0.19 pcs / ft ² ( bracket ) 2.02 pcs / m ² ( bracket )
0.15 pcs / ft ² ( bracket ) 1.64 pcs / m ² ( bracket )
0.13 pcs / ft ² ( bracket ) 1.39 pcs / m ² ( bracket )
0.12 pcs / ft ² ( bracket ) 1.26 pcs / m ² ( bracket )
0.11 pcs / ft ² ( bracket ) 1.14 pcs / m ² ( bracket )
0.38 ft / ft ² ( rails ) 1.23 m / m ² ( rails )
32 " ( 812.8mm )
4 ( 10.2 )
0.055 ( 0.311 )
18.249 ( 3.213 )
0.055 ( 0.31 )
18.309 ( 3.223 )
0.054 ( 0.31 )
18.349 ( 3.23 )
0.054 ( 0.309 )
18.37 ( 3.234 )
0.054 ( 0.309 )
18.389 ( 3.238 )
5 ( 12.7 )
0.044 ( 0.251 )
22.597 ( 3.978 )
0.044 ( 0.251 )
22.645 ( 3.987 )
0.044 ( 0.25 )
22.677 ( 3.992 )
0.044 ( 0.25 )
22.693 ( 3.995 )
0.044 ( 0.25 )
22.708 ( 3.998 )
6 ( 15.2 )
0.037 ( 0.213 )
26.714 ( 4.703 )
0.037 ( 0.212 )
26.795 ( 4.717 )
0.037 ( 0.212 )
26.849 ( 4.727 )
0.037 ( 0.211 )
26.877 ( 4.732 )
0.037 ( 0.211 )
26.903 ( 4.736 )
0.15 pcs / ft ² ( bracket ) 1.61 pcs / m ² ( bracket )
0.12 pcs / ft ² ( bracket ) 1.31 pcs / m ² ( bracket )
0.1 pcs / ft ² ( bracket ) 1.11 pcs / m ² ( bracket )
0.09 pcs / ft ² ( bracket ) 1.01 pcs / m ² ( bracket )
0.08 pcs / ft ² ( bracket ) 0.91 pcs / m ² ( bracket )
0.3 ft / ft ² ( rails ) 0.98 m / m ² ( rails )
40 " ( 1016mm )
4 ( 10.2 )
0.054 ( 0.309 )
18.355 ( 3.232 )
0.054 ( 0.309 )
18.404 ( 3.24 )
0.054 ( 0.308 )
18.436 ( 3.246 )
0.054 ( 0.308 )
18.453 ( 3.249 )
0.054 ( 0.308 )
18.469 ( 3.252 )
5 ( 12.7 )
0.044 ( 0.25 )
22.684 ( 3.994 )
0.044 ( 0.25 )
22.722 ( 4 )
0.044 ( 0.25 )
22.748 ( 4.005 )
0.044 ( 0.25 )
22.761 ( 4.007 )
0.044 ( 0.249 )
22.773 ( 4.009 )
6 ( 15.2 )
0.037 ( 0.212 )
26.825 ( 4.723 )
0.037 ( 0.211 )
26.89 ( 4.734 )
0.037 ( 0.211 )
26.934 ( 4.742 )
0.037 ( 0.211 )
26.957 ( 4.746 )
0.037 ( 0.211 )
26.977 ( 4.75 )
* Between insulation thicknesses the values can be interpolated
74 www . hilti . com