DBV Rainscreen Facade Product Technical Guide
R-VALUE TABLES
Fox HT CMU 12 '' ( 305mm ) Grouted Polyurethane Foamed in Place
Brackets : Horizontal thermally broken brackets ( medium size ) Base Material : CMU 12 " ( 305mm ) grouted polyurethane foamed in place
Vertical Bracket to Bracket Spacing 24 " Vertical ( 609.6mm ) 30 " Vertical ( 762mm ) 36 " Vertical ( 914.4mm ) 42 " Vertical ( 1066.8mm ) 48 " Vertical ( 1219.2mm )
Horizontal Stud to Stud Spacing
Exterior Insulation Thickness * in . ( cm )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
Effective U-Value BTU / h * ft ²*° F ( W / m ² K )
Effective R-Value h * ft ²*° F / BTU ( m ² K / W )
0.38 pcs / ft ² ( bracket ) 4.04 pcs / m ² ( bracket )
0.3 pcs / ft ² ( bracket ) 3.28 pcs / m ² ( bracket )
0.26 pcs / ft ² ( bracket ) 2.78 pcs / m ² ( bracket )
0.23 pcs / ft ² ( bracket ) 2.52 pcs / m ² ( bracket )
0.21 pcs / ft ² ( bracket ) 2.28 pcs / m ² ( bracket )
0.75 ft / ft ² ( rails ) 2.46 m / m ² ( rails )
16 " ( 406.4mm )
4 ( 10.2 )
0.018 ( 0.104 )
54.634 ( 9.619 )
0.018 ( 0.102 )
55.48 ( 9.768 )
0.018 ( 0.101 )
56.059 ( 9.869 )
0.018 ( 0.101 )
56.365 ( 9.923 )
0.018 ( 0.1 )
56.643 ( 9.972 )
5 ( 12.7 )
0.016 ( 0.092 )
61.966 ( 10.91 )
0.016 ( 0.091 )
62.585 ( 11.019 )
0.016 ( 0.09 )
63.004 ( 11.092 )
0.016 ( 0.09 )
63.225 ( 11.131 )
0.016 ( 0.09 )
63.425 ( 11.166 )
6 ( 15.2 )
0.015 ( 0.086 )
66.302 ( 11.673 )
0.015 ( 0.085 )
67.13 ( 11.819 )
0.015 ( 0.084 )
67.694 ( 11.918 )
0.015 ( 0.084 )
67.991 ( 11.97 )
0.015 ( 0.083 )
68.261 ( 12.018 )
0.25 pcs / ft ² ( bracket ) 2.69 pcs / m ² ( bracket )
0.2 pcs / ft ² ( bracket ) 2.19 pcs / m ² ( bracket )
0.17 pcs / ft ² ( bracket ) 1.85 pcs / m ² ( bracket )
0.16 pcs / ft ² ( bracket ) 1.68 pcs / m ² ( bracket )
0.14 pcs / ft ² ( bracket ) 1.52 pcs / m ² ( bracket )
0.5 ft / ft ² ( rails ) 1.64 m / m ² ( rails )
24 " ( 609.6mm )
4 ( 10.2 )
0.017 ( 0.099 )
57.512 ( 10.125 )
0.017 ( 0.098 )
58.135 ( 10.235 )
0.017 ( 0.097 )
58.557 ( 10.309 )
0.017 ( 0.097 )
58.779 ( 10.348 )
0.017 ( 0.096 )
58.981 ( 10.384 )
5 ( 12.7 )
0.016 ( 0.089 )
64.01 ( 11.269 )
0.016 ( 0.088 )
64.449 ( 11.347 )
0.015 ( 0.088 )
64.745 ( 11.399 )
0.015 ( 0.088 )
64.9 ( 11.426 )
0.015 ( 0.087 )
65.04 ( 11.451 )
6 ( 15.2 )
0.015 ( 0.083 )
68.327 ( 12.029 )
0.015 ( 0.082 )
68.912 ( 12.132 )
0.014 ( 0.082 )
69.306 ( 12.202 )
0.014 ( 0.082 )
69.514 ( 12.238 )
0.014 ( 0.081 )
69.702 ( 12.271 )
0.19 pcs / ft ² ( bracket ) 2.02 pcs / m ² ( bracket )
0.15 pcs / ft ² ( bracket ) 1.64 pcs / m ² ( bracket )
0.13 pcs / ft ² ( bracket ) 1.39 pcs / m ² ( bracket )
0.12 pcs / ft ² ( bracket ) 1.26 pcs / m ² ( bracket )
0.11 pcs / ft ² ( bracket ) 1.14 pcs / m ² ( bracket )
0.38 ft / ft ² ( rails ) 1.23 m / m ² ( rails )
32 " ( 812.8mm )
4 ( 10.2 )
0.017 ( 0.096 )
59.069 ( 10.399 )
0.017 ( 0.095 )
59.56 ( 10.486 )
0.017 ( 0.095 )
59.892 ( 10.544 )
0.017 ( 0.095 )
60.066 ( 10.575 )
0.017 ( 0.094 )
60.224 ( 10.603 )
5 ( 12.7 )
0.015 ( 0.087 )
65.083 ( 11.458 )
0.015 ( 0.087 )
65.423 ( 11.518 )
0.015 ( 0.087 )
65.651 ( 11.558 )
0.015 ( 0.086 )
65.771 ( 11.579 )
0.015 ( 0.086 )
65.879 ( 11.598 )
6 ( 15.2 )
0.014 ( 0.082 )
69.387 ( 12.216 )
0.014 ( 0.081 )
69.838 ( 12.296 )
0.014 ( 0.081 )
70.142 ( 12.349 )
0.014 ( 0.081 )
70.301 ( 12.377 )
0.014 ( 0.081 )
70.445 ( 12.402 )
0.15 pcs / ft ² ( bracket ) 1.61 pcs / m ² ( bracket )
0.12 pcs / ft ² ( bracket ) 1.31 pcs / m ² ( bracket )
0.1 pcs / ft ² ( bracket ) 1.11 pcs / m ² ( bracket )
0.09 pcs / ft ² ( bracket ) 1.01 pcs / m ² ( bracket )
0.08 pcs / ft ² ( bracket ) 0.91 pcs / m ² ( bracket )
0.3 ft / ft ² ( rails ) 0.98 m / m ² ( rails )
40 " ( 1016mm )
4 ( 10.2 )
0.017 ( 0.095 )
60.044 ( 10.571 )
0.017 ( 0.094 )
60.449 ( 10.642 )
0.016 ( 0.094 )
60.722 ( 10.691 )
0.016 ( 0.093 )
60.865 ( 10.716 )
0.016 ( 0.093 )
60.995 ( 10.739 )
5 ( 12.7 )
0.015 ( 0.086 )
65.745 ( 11.575 )
0.015 ( 0.086 )
66.022 ( 11.624 )
0.015 ( 0.086 )
66.208 ( 11.656 )
0.015 ( 0.086 )
66.305 ( 11.673 )
0.015 ( 0.086 )
66.393 ( 11.689 )
6 ( 15.2 )
0.014 ( 0.081 )
70.039 ( 12.331 )
0.014 ( 0.081 )
70.407 ( 12.396 )
0.014 ( 0.08 )
70.653 ( 12.439 )
0.014 ( 0.08 )
70.782 ( 12.462 )
0.014 ( 0.08 )
70.899 ( 12.482 )
* Between insulation thicknesses the values can be interpolated
70 www . hilti . com