Cold Link Africa October 2026 | Page 14

FEATURE
INCORPORATING COLD CHAIN
For some big quick service restaurant chains, we tested chicken nuggets and burger patties. The correlation data shows that we can model core temperature from ambient reliably,” Tomanek explained.
Therefore, there’ s a growing library of product profiles, and as demand appears from industry for specific categories, those can be formally tested and added.
This is where the economics shift. Instead of installing more probes and throwing away more product, you:
• Measure ambient air as usual.
• Select the appropriate product profile in the software.
• Let the algorithm calculate a realistic product core temperature curve.
• Trigger alarms based on simulated core temperature, not raw ambient spikes.
The result, in Tomanek’ s example, is up to a two‐thirds reduction in alarms – but with greater alignment to true product risk.“ Having an algorithm in a system is much cheaper than additional hardware, and definitely much cheaper than using real product.”
Because the sensor is still measuring air, operators can keep a fast‐reacting ambient alarm as an early warning, but reserve core temperature alarms for when actual product safety or quality is at stake.“ You can set it however you want,” Tomanek confirmed.“ You might have an ambient alarm to tell you something is going on, but you know you don’ t necessarily need to act yet. When the core temperature alarm comes, that’ s when you know it’ s time to move.”
Tomanek links this directly to food waste and brand protection, arguing that better monitoring can reduce unnecessary interventions, such as discarding perfectly safe product after minor ambient temperature spikes, while also preventing silent failures where product has been thermally abused without detection. Ultimately, this should improve shelf-life performance and avoid the damaging customer experience of a product testo 164 t1 application kitchen glasses. deteriorating before its printed expiry date.
Supplied by Testo
TURNING MEASUREMENTS INTO ACTION
Instrumentation is only valuable if the data it generates leads to informed decisions. According to Johan Ferreira, co-founder of Coldcubed, many food businesses still rely on manual temperature logs that are incomplete, inaccurate or only filled in after the event, making it difficult to identify the cause of cold chain failures or demonstrate compliance.
" The biggest challenge isn ' t a lack of data. It ' s having reliable data that can be trusted and presented in a way that people can act on," says Ferreira. Modern monitoring systems address this by combining strategically positioned
temperature sensors with live dashboards that continuously display product conditions rather than simply measuring air temperatures within a cold room. By placing sensors around products and throughout facilities, operators gain a far more accurate picture of what the product is actually experiencing.
For engineers and facility managers, this transforms instrumentation from a compliance exercise into an operational tool. Continuous monitoring allows temperature deviations to be detected before product quality is compromised, while time-stamped records provide objective evidence when investigating disputes or demonstrating
© Cold Link Africa
Johan Ferreira, co-founder of Coldcubed.
regulatory compliance. The same data can also identify opportunities to reduce energy consumption by highlighting areas where refrigeration systems are overcooling to compensate for operational practices such as frequent door openings. Ferreira believes the real value lies not in collecting more data, but in presenting it in a way that enables rapid decision-making. " Data on its own has very little value. It needs to be translated into information that clearly shows trends, exceptions and risks so that operators can respond before a small problem becomes a major one," he says.
CASE STUDY: THE FOUNDATION OF INTELLIGENT ENVIRONMENTAL
CONTROL
The move from measurement to intelligent control depends on a deceptively simple principle: a control system can only make a good decision if it receives a reliable picture of the environment.
This makes the performance of the sensor itself increasingly important. Accuracy is obviously critical, but resolution, response time, reliability and correct positioning can be equally significant. A sensor that responds too slowly, has developed drift or is positioned
where it does not represent the actual conditions being controlled can cause an automated system to respond to an inaccurate picture of its environment.
A Keystar Industries hatchery automation project provides a useful illustration. The facility requires extremely precise environmental control during a 21-day incubation cycle, with temperature maintained within a narrow tolerance. But temperature is only one of the variables involved. Relative humidity, oxygen concentration, carbon dioxide, airflow and other environmental conditions also need to be monitored and incorporated into the control strategy.
The challenge becomes particularly demanding as the embryos develop and their heat output changes. During hatching, thousands of chicks can begin generating metabolic heat almost simultaneously, creating a rapidly changing thermal load. Keystar ' s control system combines continuous environmental measurement with an adaptive control algorithm based on PID principles( Proportional – Integral – Derivative, a common control-system method used to automatically adjust a system in response to changes in measured conditions), allowing the system to respond to changing conditions without excessive overshoot or oscillation.
The project demonstrates why measurement should not be regarded simply as an input to a display or data logger. In an automated system, the measurement is part of the control loop: sensors provide the information, the controller interprets it and the equipment responds.
Sensor placement is therefore an important engineering consideration. The point at which a parameter is measured does not necessarily represent the condition experienced by the equipment, process or product being protected. Airflow patterns, heat sources, stratification and local conditions can all influence the reading. Multiple measurement points may also be required where conditions vary significantly within a space.

14