     Combined perimeter and under-slab insulation values
Table 3. Concrete slab on ground with 30mm edge insulation and selected under slab insulation thickness
Wall
stud depth
(mm)
ClimaFoam ®
thickness
(mm)
Area/perimeter ratio (Total slab area ÷ the total length of the perimeter)
1.3	 1.9	 2.2	2.5	 2.8	3.1	 4
Total construction R-Value (m K/W)
2
90
30	 1.05	1.33	 1.46	1.59	1.73	1.85	2.22
40	 2.03	2.31	 2.44	2.58	2.71	2.84	3.21
50	 2.70	2.98	 3.11	3.25	3.38	3.51	3.88
100*	 4.37	4.66	 4.79	4.92	5.05	5.18	5.56
140
30	 1.13	1.44	 1.58	1.73	1.86	2.00	2.40
40	 2.12	2.43	 2.57	2.71	2.85	2.99	3.39
50	 2.79	3.09	 3.24	3.38	3.52	3.66	4.05
100*	 4.46	4.76	 4.91	5.05	5.19	5.33	5.72
* 2 layers of 50mm