BriskHeat Product Catalog - English 14th Edition RevD | Page 119

HOT BONDERS
Your Heating Specialist since 1949
ACR ® 3 Hot Bonder
HOT BONDERS
Specifications
General
• Single or dual zone
• 8.4 ” ( 213mm ) touch screen
• USB port for data transfer ( USB flash disk included )
• Input ground fault interrupter breaker protected
• Audible and visual alarms for high and low temperture / vacuum limits
• Data logs digitally or through built-in printer : prints and records real-time status of cure including program parameters
• UL Listed
Power
• Universal input voltage : 100-130VAC , 200-240VAC
• MAINS supply voltage fluctuations up to ± 10 % of the nominal voltage
• Transient over voltages typically found on a Category II power source : i . e . a lighting circuit .
• Frequency : 50-60Hz
• 30 amps maximum per zone
Vacuum
• Dual vacuum system : Built-in electric vacuum pump and vacuum venturi for each zone
• Pressure : 28 ” ( 13.8PSI )
• Ability to manually adjust pressure for each zone
Temperature Control
• Cures up to 1400 ° F ( 760 ° C )
• 10 thermocouple sensor inputs per zone
• Accepts J-type thermocouple connectors
• Accuracy : ± 3 ° F ( 1.67 ° C )
• Monitors all thermocouples for alarms
Environment
• Intended for use in dry environments . Do not expose to wet spray .
• Altitude up to 6562ft ( 2,000m )
• Storage temperature range : -4 to 140 ° F ( -20 to 60 ° C )
• Operating temperature range : 41 to 104 ° F ( 5 to 40 ° C )
• Maximum relative humidity : 80 % for temperatures up to 88 º F ( 31 º C ) decreasing linearly to 50 % relative to humidity at 104 º F ( 40 º C )
• Pollution degree 2 ( normally only non-conductive pollution occurs , however a temporary conductivity caused by condensation must be expected )
Patent 6,976,519
COMPOSITE CURING
Toll Free : 800-848-7673 Phone : 614-294-3376 w w w . BriskHeat . c o m Email : bhtsales1 @ briskheat . com Fax : 614-294-3807 © BriskHeat Corporation . All Rights Reserved . 17-07
107