Biomet 3i Brochures Implant Compatibility List

Implant Compatibility List for NeoBiotech Implant Removal Kit NOTE: For other Manufacturers not listed, the clinician is advised to complete a "try in" by selecting a corresponding analog or implant to thread into whereby sequentially starting with the widest diameter FRS screw M2.5 followed by, in descending order, the next available diameter. This will ensure compatibility. Implant System Solution Kit Compatibility 3.3mm M1.6 YES FRS 16 3.75mm M2.0 YES FRS 20 Branemark System MK lll Groovy RP 4.0mm M2.0 YES FRS 20 Branemark System MK lll Groovy WP 5.0mm M2.5 YES FRS 25 NobelSpeedy® System MK lll Groovy NP 3.3mm M1.6 YES FRS 16 NobelSpeedy System MK lll Groovy RP 4.0mm M2.0 YES FRS 20 NobelSpeedy System MK lll Groovy WP 5.0mm M2.0 YES FRS 20 NobelSpeedy System MK lll Groovy WP 6.0mm M2.5 YES FRS 25 NobelReplace® Straight Groovy NP 3.5mm M1.8 YES FRS 18 NobelReplace Straight Groovy RP 4.0mm M2.0 YES FRS 20 NobelReplace Straight Groovy WP 5.0mm M2.0 YES FRS 20 NobelSpeedy Replace NP 3.5mm M1.8 YES FRS 18 NobelSpeedy Replace RP 4.0mm M2.0 YES FRS 20 NobelSpeedy Replace WP 5.0mm M2.0 YES FRS 20 NobelSpeedy Replace 6.0 6.0mm M2.0 YES FRS 20 NobelReplace Tapered NP 3.5mm M1.8 YES FRS 18 NobelReplace Tapered RP 4.3mm M2.0 YES FRS 20 NobelReplace Tapered WP 5.0mm M2.0 YES FRS 20 NobelReplace Tapered 6.0mm M2.0 YES FRS 20 3.5mm M1.54 SPECIAL ORDER FRS 154 Standard 3.3 RN M2.0 YES FRS 20 Standard 4.1 RN M2.0 YES FRS 20 Standard 4.8 RN M2.0 YES FRS 20 Standard 4.8 WN M2.0 YES FRS 20 Standard Plus 3.3 NN M1.6 or M1.8 Verify Standard Plus 3.3 RN M2.0 YES FRS 20 Standard Plus 4.1 RN M2.0 YES FRS 20 Standard Plus 4.8 RN M2.0 YES FRS 20 Standard Plus 4.8 WN M2.0 YES FRS 20 Tapered Effect 3.3 RN M2.0 YES FRS 20 Tapered Effect 4.1 RN M2.0 YES FRS 20 Tapered Effect 4.8 RN M2.0 YES FRS 20 Bone Level Implant 3.3 NC M1.6 or M1.8 Verify FRS 16 / FRS 18 Bone Level Implant 4.1 NC M1.6 or M1.8 Verify FRS 16 / FRS 18 Bone Level Implant 4.8 NC M1.6 or M1.8 Verify FRS 16 / FRS 18 ® Certain Internal 3.4 M1.6 YES FRS 16 Certain Internal Nobel Biocare Screw Size to use Branemark System MK lll Groovy RP ® Implant Ø Diameter Branemark System® MK lll Groovy NP Corporation 4.1 M1.6 YES FRS 16 Certain Internal 5.0 M1.6 YES FRS 16 NobelActive Straumann ® BIOMET 3i ® Product Name FRS 16 / FRS 18 This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated or disclosed without the express written consent of BIOMET 3i.