Biomet 3i Brochures Implant Compatibility List
Implant Compatibility List for NeoBiotech Implant Removal Kit
NOTE: For other Manufacturers not listed, the clinician is advised to complete a "try in" by selecting a corresponding analog or implant to thread into whereby
sequentially starting with the widest diameter FRS screw M2.5 followed by, in descending order, the next available diameter. This will ensure compatibility.
Implant System
Solution Kit
Compatibility
3.3mm
M1.6
YES
FRS 16
3.75mm
M2.0
YES
FRS 20
Branemark System MK lll Groovy RP
4.0mm
M2.0
YES
FRS 20
Branemark System MK lll Groovy WP
5.0mm
M2.5
YES
FRS 25
NobelSpeedy® System MK lll Groovy NP
3.3mm
M1.6
YES
FRS 16
NobelSpeedy System MK lll Groovy RP
4.0mm
M2.0
YES
FRS 20
NobelSpeedy System MK lll Groovy WP
5.0mm
M2.0
YES
FRS 20
NobelSpeedy System MK lll Groovy WP
6.0mm
M2.5
YES
FRS 25
NobelReplace® Straight Groovy NP
3.5mm
M1.8
YES
FRS 18
NobelReplace Straight Groovy RP
4.0mm
M2.0
YES
FRS 20
NobelReplace Straight Groovy WP
5.0mm
M2.0
YES
FRS 20
NobelSpeedy Replace NP
3.5mm
M1.8
YES
FRS 18
NobelSpeedy Replace RP
4.0mm
M2.0
YES
FRS 20
NobelSpeedy Replace WP
5.0mm
M2.0
YES
FRS 20
NobelSpeedy Replace 6.0
6.0mm
M2.0
YES
FRS 20
NobelReplace Tapered NP
3.5mm
M1.8
YES
FRS 18
NobelReplace Tapered RP
4.3mm
M2.0
YES
FRS 20
NobelReplace Tapered WP
5.0mm
M2.0
YES
FRS 20
NobelReplace Tapered
6.0mm
M2.0
YES
FRS 20
3.5mm
M1.54
SPECIAL ORDER
FRS 154
Standard
3.3 RN
M2.0
YES
FRS 20
Standard
4.1 RN
M2.0
YES
FRS 20
Standard
4.8 RN
M2.0
YES
FRS 20
Standard
4.8 WN
M2.0
YES
FRS 20
Standard Plus
3.3 NN
M1.6 or M1.8
Verify
Standard Plus
3.3 RN
M2.0
YES
FRS 20
Standard Plus
4.1 RN
M2.0
YES
FRS 20
Standard Plus
4.8 RN
M2.0
YES
FRS 20
Standard Plus
4.8 WN
M2.0
YES
FRS 20
Tapered Effect
3.3 RN
M2.0
YES
FRS 20
Tapered Effect
4.1 RN
M2.0
YES
FRS 20
Tapered Effect
4.8 RN
M2.0
YES
FRS 20
Bone Level Implant
3.3 NC
M1.6 or M1.8
Verify
FRS 16 / FRS 18
Bone Level Implant
4.1 NC
M1.6 or M1.8
Verify
FRS 16 / FRS 18
Bone Level Implant
4.8 NC
M1.6 or M1.8
Verify
FRS 16 / FRS 18
®
Certain Internal
3.4
M1.6
YES
FRS 16
Certain Internal
Nobel Biocare
Screw Size
to use
Branemark System MK lll Groovy RP
®
Implant
Ø Diameter
Branemark System® MK lll Groovy NP
Corporation
4.1
M1.6
YES
FRS 16
Certain Internal
5.0
M1.6
YES
FRS 16
NobelActive
Straumann
®
BIOMET 3i
®
Product
Name
FRS 16 / FRS 18
This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated or disclosed
without the express written consent of BIOMET 3i.