Architectural Light Fittings from SKIALIGHT Orbit, Architectural Light Fittings from SKIALIGHT | Page 121
NO FRAME
INSTALLATION STEPS
A = FREE SPACE (min. 200 mm)
B = CEILING THICKNESS
KIT CEILING THICKNESS (B) IN BETWEEN 7 MM AND 40 MM
BB5103
1 2 3 4 5
Cut the desired opening
in the ceiling Insert the kit Fix the kit with screws Adjust the height of the kit
& finish ceiling & gaps Connect electrical cables, insert
luminaire & fix with thumbscrew
FREE SPACE 200 < A < 260 A > 260 WEIGHT
1L
2L
3L
4SQ 210 X 170 MM
370 X 170 MM
520 X 170 MM
370 X 330 MM 210 X 170 MM
330 X 170 MM
480 X 170 MM
330 X 330 MM 0,5 KG
0,9 KG
1,0 KG
1,2 KG
BB
BB
BB
BB
50001
50002
50003
50007
ECONOMIC KIT ONLY WHEN CEILING THICKNESS (B) = 12,5 MM (TYPE BA13)
1 2 3 4 5
Cut the desired opening
in the ceiling Insert the economic kit Fix the economic kit with screws
& finish ceiling & gaps Connect electrical cables
& insert luminaire Adjust height with side brackets
FREE SPACE A < 200 WEIGHT
1L
2L
3L 165 X 165 MM
165 X 330 MM
165 X 480 MM 0,2 KG
0,3 KG
0,5 KG
BB 60001
BB 60002
BB 60003
Skialight
Tel 020 3514 4668
Email [email protected]
Web www.skialight.co.uk
121