Arc Advisor Comparison Pricing April 2014

ArcAD Arc Flash Analysis Software by Arcad Inc. ArcAD: Arc Flash Analysis & Label Software v3.2 • IEEE 1584 Fuse Equations • IEEE 1584 LV Circuit Breaker Equations P P P P P Lee method • System Voltage 15kV to 46kV • Gap is outside the range of the Empirical Model v5.0 P IEEE 1584 Empiricaly Derived Model • Available short circuit currents from 700A to 106kA • Switchgears, MCC, panels, cables, arc in open air • Grounding of all types and ungrounded • Gaps between conductors of 13mm to 152mm • System Voltage 208V to 15kV v4.1 P Calculation Models P P P Phase to Ground Arcs in Open Air • System Voltages up to 242kV ARCAD helps facilities create safer working environments for individuals who service electrical systems by providing On-Line and PC based software tools for Short Circuit and Arc Flash Hazard Analysis. NFPA requires that any panel likely to be serviced by a worker be surveyed and labeled. ARCAD service includes resources and tools allowing plant and facility managers and personnel to perform short circuit, incident energy, arc flash protection boundary, level of PPE calculations, and create customized arc flash warning labels themselves reducing the cost of obtaining compliance with OSHA, NFPA70E and new Canadian CSA Z462 standards. PART # PRICE Version 3.2 ARCAD32 $150.00 Version 4.1 ARCAD41 $220.00 Version 5.0 ARCAD50 ARCDC $240.00 P P P • Built-In & Expandable Circuit Protection Device Library • Evaluated Threshold Incident Energy for a Second Degree Burn P P Warning Label Information • Working distance • Available short circuit current • Arc flash boundary • Limited, restricted, prohibited shock approach boundaries • Incident energy • Hazard risk category • Equipment name • Typical clothing system • Date created P P P P • Save results • Use metric and/or imperial units • Create labels in electronic JPG and BMP formats • Create color and black-and-white labels P P P P • Initial arc pressure • Arc Explosive TNT equivalent P P P P P P P P P P P P P P P P • Save equipment configuration • Alternate label layouts • Create label in electronic PDF format $290.00 DC Advisor Direct Current ( DC ) Arcs • System Voltage 125 to 2000V • Short Circuit Current 1 to 50kA • Circuit Time Constant 0 to 50msec • Fixed or Variable Gap between Conductors DC Language • English, French, Spanish • Portuguese Other • One month free access to ARCAD online short circuit calculator 1-866-777-1360 1-330-777-8818 www.creativesafetysupply.com