Chemical Anchor Selector Chart - EN Chemical Anchor Selector Chart - EN January 2023

Chemical — Adhesives

ANCHOR SELECTOR

Chemical — Adhesives

For Use with
Concrete Condition
Acceptable Drilling Method
ICC-ES , IAPMO-ER Approvals or Hilti Technical Data ( ■ )
Base Material Temperature at Installation
Cure Time ( Working Time )
Environmental Qualifications
Hybrid Adhesives ( Fast Cure )
Rebar
Anchor Rod
HIT-HY 200-R V3 ■ ■ ■
HIT-HY 200-A V3 ■ ■ ■
KH-EZ
Dry
Water
Saturated
■ No Load Reduction
■ No Load Reduction
Water Filled Holes
Submerged
Hammer Drilling
Hollow Drill Bit
Diamond Core
SafeSet Installation
Uncracked
Cracked
Seismic
Grouted
Masonry
Cracked Masonry
Hollow Masonry
■ ■ ■ ■ ■ ESR-4868 ESR-4868 ESR-4868 / ESR-4878 ESR-4878 14 ° F
( -10 ° C )
■ ■ ■ ■ ■ ESR-4868 ESR-4868 ESR-4868 / ESR-4878 ESR-4878 14 ° F
( -10 ° C )
Hollow Brick
Hollow core
Multi Wythe Brick
Minimum
Maximum
Lowest
Install
Temperature
104 ° F ( 40 ° C )
104 ° F ( 40 ° C )
20 hr . ( 3 hr )
7 hr . ( 1.5 hr )
Mid Install Temperature ( 68 ° F / 20 ° C )
1.5 hr . ( 15 min )
45 min ( 7 min )
Highest Install Temperature
1 hr . ( 6 min )
30 min ( 3 min )
NSF Approval
Green Building Materials Certification
■ ■
■ ■
HIT-HY 100 ■ ■ ■ ■ ■ ■ ■ ESR-3574 ESR-3574 ESR-3574 / ER-547
ER-547
14 ° F ( -10 ° C )
104 ° F ( 40 ° C )
12 hr . ( 3 hr )
1 hr . ( 8 min )
30 min ( 2 min )
■ ■
HIT-HY 270 ■ ■ ■ ■ ■ ■ ■ ESR-4143 ESR-4143 ■ ESR-4143 ESR-4143 ■ ESR-4144
23 ° F ( -5 ° C )
104 ° F ( 40 ° C )
6 hr . ( 10 min )
1.5 hr . ( 4 min )
20 min ( 1 min )
■ ■
HIT-ICE ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
-10 ° F ( -23 ° C )
90 ° F ( 32 ° C )
36 hr . ( 1.5 hr )
1 hr . ( 5 min )
35 min ( 1 min )
■ ■
Epoxy Resins ( Slow Cure )
HIT-RE 500 V3 ■ ■ ■
■ No Load Reduction
■ ■ ■ ■ ■ ■ ESR-3814 ESR-3814 ESR-3814
23 ° F ( -5 ° C )
105 ° F ( 41 ° C )
168 hr . ( 2 hr )
6.5 hr . ( 25 min )
4 hr . ( 10 min )
■ ■
HIT-RE 100 ■ ■ ■ ■ ■ ■ ■ ■ ■ ESR-3829 ESR-3829 ESR-3829
41 ° F ( 5 ° C )
104 ° F ( 40 ° C )
72 hr . ( 2.5 hr )
12 hr . ( 30 min )
4 hr . ( 12 min )
■ ■
Dual Action Anchors ( Immediate Loading )
Kwik-X ■ ■
■ No Load Reduction
■ ■ ■ ■ ESR-5065 ESR-5065 ESR-5065
-18 ° F ( -28 ° C )
104 ° F ( 40 ° C )
24 hr 0.5 min 0.5 min ■ ■
Inorganic Adhesives ( Fire-Resistant )
HIT-FP 700 R ■ ■ ■ ■ ■ ■ ■ ■ ■
40 ° F ( 5 ° C )
104 ° F ( 40 ° C )
18 days 7 days 4 days ■ ■
Adhesive Capsules ( Fast Cure )
HVU2 ■ ■
■ No Load Reduction
■ ■ ■ ■ ESR-4372 ESR-4372 ESR-4372
14 ° F ( -10 ° C )
104 ° F ( 40 ° C )
5 hr 5 min 5 min ■ ■
DBS • 12 / 22
Hilti , Inc . ( U . S .) 1-800-879-8000 | en español 1-800-879-5000 www . hilti . com
Hilti ( Canada ) Corporation 1-800-363-4458 www . hilti . ca
Diamond coring only when using TE-YRT ( roughening tool ) or HIT-Z rod . Times are doubled when water saturated / filled / underwater . Tested per ETA