ALS Product catalogues WASTE | Page 8

Waste acceptance criteria ( WAC ) - inert waste ( dry matter )
Parameter Limit value * ( mg / kg )
LOQ ( mg / kg DW )
BTEX ( sum ) benzene toluene ethylbenzene o-xylene m , p-xylene
6 0.5
Mineral oil ( C10-C40 ) 500 20
PAH ( sum of 12 parameters )** naphtalene phenanthrene anthracene fluoranthene pyrene benzo ( a ) anthracene chrysene benzo ( b ) fluoranthene benzo ( k ) fluoranthene benzo ( a ) pyrene benzo ( ghi ) perylene indeno ( 123cd ) pyrene
PCB ( sum of 7 congeners ) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
80 0.12
1 0.14
TOC ( total organic carbon ) 30 000 100
* Limit values from Council Decision 2003 / 33 / EC . ** Number of parameters and limit value set by member state . Minimum sample amount : 0.5 kg dry waste
Waste acceptance criteria ( WAC ) - non-hazardous waste ( water leaching )
Parameter
Single step ( L / S = 10 )
Limit value ( mg / l )
Two stage * ( L / S = 2 , L / S = 8 )
Percolation test ( usually L / S = 0.1 )
ALS LOQ ( mg / l )
As 0.2 0.2 0.3 0.05 Ba 10 15 20 0.003 Cd 0.1 0.3 0.3 0.005 Cr total 1 2 2.5 0.001 Cu 5 12.5 30 0.01 Hg 0.02 0.025 0.03 0.001 Mo 1 2.5 3.5 0.02 Ni 1 2.5 3 0.02 Pb 1 2.5 3 0.05 Sb 0.07 0.1 0.15 0.05 Se 0.05 0.15 0.2 0.025 Zn 5 12.5 15 0.01 chloride 1500 5000 8500 1 fluoride 15 30 40 0.2 sulphate 2000 5000 7000 5 DOC 80 190 250 0.5 TDS 6000 20000 - 10 pH > 6 > 6 - 1
* Value mentioned for L / S = 2 L / kg . Minimum sample amount :
0.5 kg dry waste
8 Product catalogue Waste RIGHT SOLUTIONS • RIGHT PARTNER