Mercury
Parameter LOQ
(mg/sample) Minimum sample amount
mercury - quartz filter or external
amalgator 0.05 filter or external amalgamator
representing one ambient air sampling
mercury from atmospherical
precipitation 2.5 glass, 50 ml
Method: AAS-AMA
Hexavalent chromium - Cr (VI)
Parameter
LOQ
(µg/sample) Minimum sample amount
0.1 filter representing 1 ambient air sampling
chromium (VI) – leach of filter
Method: ion chromatography
*Radiello is a patented diffusive sampler.
Metals on filters
LOQ*
(µg/sample) LOQ**
(µg/sample) Ag 0.1 - Mo 0.5 -
Al 1 - Mn 0.1 0.025
As 0.5 0.05 Ni 0.5 0.25
B 5 - Na 0.5 -
Ba 0.5 - Pb 0.5 0.025
Be 0.01 0.01 Sb 0.5 0.025
Ca 5 - Se 0.5 0.25
Cd 0.05 0.025 Sn 0.5 0.25
Co 0.1 0.025 Te 0.5 0.25
Cr 0.25 0.15 Ti 0.5 Cu 0.1 0.05 Tl Fe 5 - U - 0.01
K 5 - V 0,5 0.05
Li 0.5 - Zn 1 0.25
5 -
Parameter
Mg
Method:
Parameter
LOQ*
(µg/sample)
LOQ**
(µg/sample)
-
0.025
* ICP-OES, **ICP-MS
Analysis by scanning electron microscope (SEM)
Parameter
identification and number of fibers on filter
identification of fibers in dust/material
asbestos in material (semi-quantitative analysis)
number of spores/mould on filter
qualitative and quantitative analysis of particles on filter
RADIOMETRIC ANALYSIS
PLEASE CONTACT US FOR
FURTHER INFORMATION
9