PACKAGED ROOFTOP UNITS  48EN/EH 241-600 Options ■■ Compressors in tandem. This setting improves the management of stages, and therefore the energy efficiency of the unit. ■■ Dampers with spring for automatic closing in case of a tension cut. This is compulsory if the outdoor temperature is lower than -8ºC WB. ■■ Assembly with mixing box and free-cooling: 2 dampers (motorised): -- MS: Outdoor air intake with damper, interlocked with return damper. 3 dampers (motorised): -- MA: Axial return and air extraction fan with duct (to prevent recirculation). -- MC0: Lower MC0 radial centrifugal return fan. ■■ Electrical heater for antifreeze protection of dampers of mixing boxs. This is compulsory if the outdoor temperature is lower than -12ºC WB. M000 MS00 N R I MA00 I MC00 N E E I R Indoor air circulation Designation of the assembly R = Air return I = Air inlet N= New air inlet E = Air extraction 0 = Standard S = 2 dampers A = Axial return fan C0 = Radial centrifugal return fan ■■ High-powered axial fans in the outdoor circuit. ■■ Electronic EC axial fans in the outdoor circuit which adapt their rotation speed to the installation requirements, thereby reducing electricity consumption, the sound level at partial charge and improving the average seasonal output of the unit. ■■ High-pressure outlet fan of the indoor circuit (for available pressure above 30 mm.a.c). Centrifugal fans, coupling by pulleys and belts with an impeller with back-curved blades. R N R ■■ Condensates drain pan for the indoor circuit in stainless steel (standard pan in galvanised steel). ■■ Control of the overpressure with the MC0 assembly. ■■ Soft starter of the outlet fan which prolongs the set time mainly aimed at installations with cloth ducts. Compulsory for motors with an output of 15 kW and above. ■■ Stop-drop in the outdoor air intake. ■■ Gravimetrics filters G4. ■■ Opacimetric folded filters F6 to F9 + gravimetric filters G4. ■■ Differential pressostat for clogged filter detection (recommended). ■■ Electrical power supply with neutral. ■■ Outdoor coil protection grille. ■■ Coils (outdoor and/or indoor) with copper pipes and copper fins. ■■ Coils (outdoor and/or indoor) with copper pipes and aluminium fins with polyurethane and blygold polual coating. ■■ Thermal and acoustic isolation 50 mm thick, with fire classification Euroclase A2-s1, d0. ■■ Compressor with protection for low temperature (supplementary crankcase heater). This is compulsory if the outdoor temperature is lower than -8ºC WB. ■■ Numeration of components in the electrical panel. ■■ Numeration of wired. ■■ Smoke detecting station in accordance with the NF S 61-961 standard. ■■ Air quality probe for installation in the environment or in duct to enable measuring CO2 and/or volatile compounds. ■■ Standardised pre-assembly frames made of galvanised steel panelling, thermally insulated. Adjustable height. ■■ Shock absorbers made of rubber. ■■ Skis for transporting in closed container. CONTROLS ■■ Electrical heater for protection of the components of the electric panel. This is compulsory if the outdoor temperature is lower than -8ºC WB. With an outdoor temperature ower than -16ºC WB will be compulsory a reinforced resistance. ■■ Energy meter. AIR TREATMENT I ■■ Tropicalised unit. It includes varnish for the elements in the electric panel, tropicalised indoor and outdoor fans. C A R R I E R 2 0 1 6 / 2 0 1 7 841