AHI Carrier Catalog | Page 839

PACKAGED ROOFTOP UNITS  48EN/EH 241-600 Physical data 241 321 361 242 322 362 420 485 540 600 kW kW 58,9 21,4 2,7 72,1 28,1 2,6 82,7 32,7 2,5 60,3 21,1 2,9 73,6 27,5 2,7 84,8 32,0 2,6 101,7 33,0 3,1 110,3 37,0 3,0 123,3 42,8 2,9 135,5 49,8 2,7 kW kW 62,2 18,2 3,4 76,7 21,8 3,5 92,3 26,6 3,5 62,2 17,4 3,6 76,1 20,9 3,6 91,6 25,5 3,6 105,5 31,2 3,4 115,5 35,3 3,3 129,0 39,1 3,3 143,4 43,6 3,3 48EN/EH Cooling Cooling capacity * Power input*** EER performance Heating 30.000 m3/h mm.w.c 4 Axial 2 mm 2 x 800 kW 2 x 2,0 / 1,3 r.p.m. 895 / 685 * ** *** **** C 12.000 14.300 m3/h mm.w.c 12 12 Centrifugal 2/2 kW 2 x 1,5 2 x 2,2 kW 2 x 1,13 2 x 1,67 r.p.m. 847 939 4 2 x 630 + 2 x 800 2 x 0,7 / 0,4 + 2 x 2,0 / 1,3 875 / 650 895 / 685 15.900 12 12.000 12 14.300 12 15.900 12 18.000 12 18.200 12 20.400 15 24.000 15 2x3 2 x 1,1 2 x 2,2 2 x 2,2 2 x 2,2 2 x 2,2 2 x 3 2x4 2 x 2,11 2 x 0,93 2 x 1,35 2 x 1,68 2 x 1,70 2 x 1,74 2 x 2,40 2 x 3,42 995 762 829 870 708 713 790 860 Scroll 2 2 2 Copeland 3MAF 32cST, Danfoss POE 160SZ, ICI Emkarate RL 32CF, Mobil EAL Artic 22CC 2 x 3,3 2 x 3,3 2 x 6,2 2 x 3,3 2 x 3,3 2 x 6,2 2 x 6,2 2 x 6,2 2 x 6,2 2 x 6,2 l Natural or propane PCH-72 kW 73 mm.w.c 11,4 16,2 20,0 PCH-200 197 5,7 8,1 10,0 12,8 13,1 16,5 22,8 400 V / III ph / 50 Hz (±10%) 3 Wires + Ground A A A A A 58,0 8,6 7,2 2,0 75,8 70,0 8,6 10,0 2,0 90,6 72,0 8,6 13,8 2,0 96,4 58,0 8,6 5,4 2,0 74,0 70,0 8,6 10,0 2,0 90,6 72,0 8,6 10,0 2,0 92,6 87,0 11,2 10,0 2,0 110,2 102,0 11,2 10,0 2,0 125,2 116,0 11,2 13,8 2,0 143,0 130,0 11,2 18,0 2,0 161,2 19,8 41,3 27,0 56,4 18,8 39,3 20,1 42,0 27,4 57,2 42,5 88,7 42,4 88,5 51,0 106,5 51,0 106,5 1.717 3.926 2.205 2.095 1.723 1.942 4.816 2.205 2.095 2.360 2.402 2.459 2.512 R-410A 2.088 kg 18,4 tCO2eq 38,4 mm mm mm kg 3.326 2.205 2.095 1.497 1.581 1 1/4” adaptor 1.806 Cooling capacity calculated in accordance with the EN-14511 standard given for indoor temperature conditions 27ºC, 50% RH and 35ºC outdoor temperature. Heating capacity calculated in accordance with the EN-14511 standard given for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature. Total power input by compressors and motorised fans under nominal conditions, calculated in accordance with the EN-14511 standard. Climatic warming potential of a kilogram of fluorinated greenhouse gas in relation to a kilogram of carbon dioxide over a period of 100 years. A R R I E R 2 0 1 6 AIR TREATMENT Indoor circuit supply fan Nominal air flow Available static pressure Type Number / no. turbines Motor output Power input Speed Compressor Type Number of compressors Number of circuits Number stages Oil type Volume of oil Gas burner Gas type Standard model Max. heating capacity Pressure drop Electrical features Electrical power supply Power supply Maximum absorbed current Compressor(s) Outdoor fan(s) Indoor fan Control Total Refrigerant Type Global warming potential (GWP) **** Charge Environment impact Dimensions Length Width Height Weight Condensate outlet Ø 42.000 / 2 0 1 7 839 CONTROLS Heating capacity ** Power input *** COP performance Outdoor circuit fan Nominal air flow Available static pressure Type Number Diameter Output Speed