Physical Data (EN-14511-2011)
50EN/EH
Cooling
Cooling capacity *
Power input ***
EER performance
Heating
Heating capacity **
Power input ***
COP performance
Outdoor circuit fan
Nominal air flow
Available static pressure
Type
Number
Diameter
Output
AIR TREATMENT
Speed
Indoor circuit supply fan
Nominal air flow
Available static pressure
Type
Number / no. turbines
Motor output
Power input
Speed
Compressor
Type
Number of compressors
Number of stages
Number of circuits
Oil type
Volume of oil
Electrical characteristics
Electrical power supply
Power supply
Maximum absorbed current
Compressor(s)
Outdoor fan(s)
Indoor fan
Control
Total
Refrigerant
Type
Global warming potential (GWP) ****
Charge
Environment impact
Dimensions
Length
Width
Height
Weight
Condensate outlet Ø
*
**
***
****
650
720
840
960
1100
1200
kW
kW
152,1
48,2
3,2
168,7
55,6
3,0
199,9
66,1
3,0
218,9
75,6
2,9
257,5
88,2
2,9
280,8
99,9
2,8
kW
kW
158,9
43,8
3,6
177,1
50,0
3,5
207,7
60,0
3,5
230,1
67,0
3,4
267,6
81,9
3,3
293,1
91,1
3,2
55.000
56.000
m3/h
mm.w.c 4
Axial
4
mm
2 x 630 + 2 x 800
kW
2 x 0,7 / 0,4 +
2 x 2,0 / 1,3
r.p.m.
875 / 650
895 / 685
75.000
75.000
112.500
112.500
27.500
m3/h
mm.w.c 17,5
Centrifugal
mm
2/2
kW
2x4
kW
5,15
r.p.m.
654
30.000
17,5
33.000
17,5
37.000
17,5
42.000
17,5
46.000
17,5
2x4
6,21
677
3/3
3x3
5,87
677
3x3
7,49
714
1/3
18,5
13,47
873
22
16,62
916
l
4 x 800
4 x 2,0 / 1,3
6
6 x 800
6 x 2,0 / 1,3
895 / 685
895 / 685
Scroll
4
4
2
4
Copeland 3MAF 32cST, Danfoss POE 160SZ, ICI Emkarate RL 32CF, Mobil EAL Artic 22CC
4 x 3,3
4 x 6,2
4 x 6,2
4 x 6,2
4 x 6,2
4 x 6,2
400 V / III ph / 50 Hz (±10%)
3 Wires + Ground
A
A
A
A
A
100,4
11,2
18,0
1,8
131,4
R-410A
2.088
kg
35,0
tCO2eq 73,1
mm
mm
mm
kg
122,0
11,2
18,0
1,8
153,0
140,6
17,2
20,7
1,8
180,3
159,2
17,2
20,7
1,8
198,9
182,2
25,8
37,0
1,8
246,8
205,2
25,8
42,0
1,8
274,8
41,0
85,6
44,0
91,9
46,0
96,0
57,0
119,0
58,0
121,1
2.374
6.316
2.205
2.095
3.022
3.135
4.816
2.205
2.095
2.093
2.152
1 1/4” adaptor
2.277
Cooling capacity calculated in accordance with the EN-14511-2011 standard given for indoor temperature conditions 27ºC, (19ºC WB) and 35ºC outdoor temperature.
Heating capacity calculated in accordance with the EN-14511-2011 standard given for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature.
Total power input by compressors and motorised fans under nominal conditions, calculated in accordance with the EN-14511-2011 standard.
Climatic warming potential of a kilogram of fluorinated greenhouse gas in relation to a kilogram of carbon dioxide over a period of 100 years..
828
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7