HORIZONTAL PACKAGE AIR CONDITIONNERS  50HB/HF Physical data 50HB/HF Weight 65 80 90 120 160 kW kW 12,5 5,2 2,38 15,3 6,6 2,30 20,1 7,4 2,70 21,5 8,5 2,53 27,1 11,0 2,47 35,9 15,4 2,33 kW kW 14,2 4,8 2,93 16,9 5,7 2,96 21,1 6,4 3,29 23,1 7,4 3,13 30,5 9,3 3,28 41,0 13,3 3,10 4.600 9 6.500 10 7.000 10 10.000 12 12.200 12 1,5 1,01 1.207 1,5 1,14 828 2,2 1,33 859 2,2 1,37 589 3,0 2,03 630 3.100 5,0 4.000 6,2 4.600 6,2 6.000 6,2 7.000 7,5 1,1 0,63 1.340 1,1 0,67 1.051 1,5 0,94 1.150 1,5 1,20 988 3,0 1,94 1.168 m3/h 4.100 mm.w.c 9 Centrifugal 1 kW 1,1 kW 0,77 r.p.m. 1.125 m3/h 2.500 mm.w.c 5,0 Centrifugal 1 kW 0,55 kW 0,35 r.p.m. 1.115 Scroll 1 1 Copeland 3MAF 32cST, Danfoss POE 160SZ, ICI Emkarate RL 32CF, Mobil EAL Artic 22CC 1,6 1,6 1,6 3,0 3,3 3,3 l 400 V / III ph / 50 Hz (±10%) 3 Wires + Ground A A A A A 15,0 2,7 1,6 2,0 21,3 19,0 3,6 2,7 2,0 27,3 19,0 3,6 2,7 2,0 27,3 22,0 5,0 3,6 2,0 32,6 29,0 5,0 3,6 2,0 39,6 35,0 6,9 6,9 2,0 50,8 kg t CO2e R-410A 2.088 2,5 5,2 3,0 6,3 4,5 9,4 4,9 10,2 5,0 10,4 6,2 12,9 mm mm mm 1.420 1.065 576 1.420 1.065 576 1.760 1.414 701 1.760 1.414 701 2.300 1.820 824 2.300 1.820 824 kg 245 253 332 375 472 521 Ø Condensate evacuation AIR TREATMENT Cooling Cooling capacity * Power input *** EER performance Heating Heating capacity ** Power input *** COP performance Outdoor circuit fan Nominal air flow Available static pressure Type Number Motor output Power input Speed Indoor circuit fan Nominal air flow Available static pressure Type Number Motor output Power input Speed Compressor Type Compressor number Circuit number Oil type Voulme of oil Electrical characteristics Electrical power supply Power supply Maximum absorbed current Compressor Outdoor fan Indoor fan Control Total Refrigerant Type Global warming potential (GWP) **** Charge Environment impact Dimensions Length Width Height 55 * Cooling capacity calculated in accordance with the EN-14511-2013 standard given for indoor temperature conditions 27ºC, 50% RH and 35ºC outdoor temperature. ** Heating capacity calculated in accordance with the EN-14511-2013 standard given for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature. *** T otal power input by compressor and motorised fans under nominal conditions calculated in accordance with the EN-14511-2013. **** Climatic warming potential of a kilogram of fluorinated greenhouse gas in relation to a kilogram of carbon dioxide over a period of 100 years. C A R R I E R 2 0 1 6 / 2 0 1 7 767 CONTROLS 3/4”