CLOSE CONTROL UNIT  50CO Features and advantages ■■ Casing -- Double-wall construction (M0/A1 fire resistance) -- Detachable pre-coated grey (RAL 7035 and RAL 7024) panels -- 0.8mm painted pre-coated exterior panel -- 25 mm mineral wool insulation -- 0.8 mm galvanised interior panels ■■ Filtration -- Filter cells: G4, F7 -- Holds filter cells pressed against the counter frame with the gasket directly on the filter cells -- Filter restriction monitored by an analogue sensor. Restriction values displayed by controller ■■ Cooling coil section -- Copper tubes, aluminium fins -- Aluminium or stainless steel condensate drain pan -- Stainless steel coil casings (option) -- Fitted and connected two-way or three-way control valve ■■ Ventilation section -- Plug fan coupled with an induction motor or an electronically commutated (EC) motor -- EC motor: fan speed adjusted by a potentiometer or automatically by the controller based on room loads (system air contro l) -- The fan also has a ModBus card which allows faults and settings such as the actual power input, current, rotation speed, etc. to be transmitted ■■ Electrics box Electrical power and control box consisting of: -- Power supply (three phase, 400 V, earth) -- Main disconnect switch -- Protected transformer (three phase, 400 V, 50 Hz) -- All electrical components protected and controlled by a circuit breaker and contact switch -- Automatic CARRIER CCU Controller -- Monitoring of return air dry-bulb temperature -- Monitoring of return air humidity during supply or dehumidification -- Options: water leak detection -- Remote control and fault summary contact ■■ Accessories (options) -- Free cooling box -- Support base for delivering supply air into a raised floor -- Cased base with grille or damper -- Supply plenum -- Motorised intake damper -- Fire thermostat -- Supply air low-limit sensor -- LON gateway -- Management of pressure in raised floor -- Changeover thermostat Controls C A R R I E R 2 0 1 6 / 2 0 1 7 CONTROLS AIR TREATMENT ■■ CARRIER CCU Controller control system -- 160-character display shows operating instructions, operating states, faults and solutions. Configurable controller. -- Two fault levels -- Monitoring of running times -- RS485 output with a Jbus / ModBus protocol -- Master/slave operation possible -- LON gateway (optional) -- Management of pressure in raised floor (optional) -- Changeover thermostat (optional) -- Bus management between the centrifugal plug fan and the controller -- Transmits fan faults and settings such as the actual power input, current, rotation speed, etc. to the controller 763