AHI Carrier Catalog | Page 746

Environmentally balanced ■■ Non-ozone depleting refrigerant R410A -- Chlorine-free refrigerant of the HFC group with zero ozone depletion potential -- Very efficient - gives an increased energy efficiency ratio (EER, COP and ESEER) ■■ Leak-tight refrigerant circuit -- Brazed refrigerant connections for increased leaktightness (factory nitrogen charge) -- Verification of pressure transducers and temperature sensors without transferring refrigerant charge. Superior reliability ■■ Auto-adaptive control -- Automatic compressor unloading in case of abnormally high condensing pressure. If an anomaly occurs (e.g. fouled air heat exchanger coil, fan failure) the condensing unit continues to operate, but at reduced capacity. ■■ Exceptional endurance tests -- Corrosion resistance tests in salt mist in the laboratory -- Accelerated ageing test on components that are submitted to continuous operation: compressor piping, fan supports -- Transport simulation test in the laboratory on a vibrating table. ■■ State-of-the-art concept -- Cooperation with specialist laboratories and use of limit simulation tools (finite element calculations) for the design of the critical components, e.g. motor supports, suction/discharge piping, etc. Controls Pro-Dialog+ control Carrier Comfort Network (CCN) operating mode Carrier Comfort Network (CCN) operating mode Remote operating mode with volt-free contacts (standard) -- S  tart/stop: opening of this contact will shut down the unit -- Alarm indication using an LED: availability of a volt-free contact that indicates the presence of a major fault that has led to the shut-down of one or two refrigerant circuits. -- User safety: this contact can be used for any customer safety loop, opening of the contact generates a specific alarm. Operating limits, Standard units Operating range 50 45 38RBS Minimum Maximum Evaporator Suction temperature (dew point) °C -5 15 Condenser Entering air temperature* -10 48 °C * For transport and storage of the 38RBS units the minimum and maximum allowable temperatures are -20°C and +48°C. It is recommended that these temperatures are used for transport by container. Option 28 allows stable unit operation at air temperatures below -10°C and down to -20°C. 40 Room temperature, °C AIR TREATMENT Pro-Dialog+ combines intelligence with operating simplicity. The control constantly monitors all machine parameters and precisely manages the operation of compressors and fans for optimum energy efficiency. ■■ Energy management -- Seven-day internal time schedule clock: permits unit on/off control and operation at a second setpoint -- Setpoint reset by the user via a room sensor (option). ■■ Integrated features -- Night mode: capacity and fan speed limitation for reduced noise level -- Solenoid valve control for evaporator pumpdown (valves supplied as a kit with the unit). A simple two-wire communication bus between the RS485 port and the Carrier Comfort Network offers multiple remote control, monitoring and diagnostic possibilities. Carrier offers a vast choice of control products, specially designed to control, manage and supervise the operation of an air conditioning system. Please consult your Carrier representative for more information on these products. 35 30 25 20 15 10 5 0 -5 -10 -15 -10 -5 0 5 10 20 15 Suction temperature (dew point), °C 746 C A R R I E R 2 0 1 6 / 2 0 1 7