AHI Carrier Catalog | Page 69

DUCTABLE AIR-COOLED LIQUID CHILLERS  30RBY 017-040 Physical data 30RBY 017 021 026 033 040 15.7 20.3 27.0 32.3 41.9 C1 Nominal capacity kW kW/kW C1 EER C1 Eurovent Energy Class C2 Nominal capacity kW EER kW/kW 2.95 2.78 3.30 3.48 3.83 ESEER kW/kW 2.78 2.77 2.97 3.15 2.98 dB(A) 80.0 80.0 91.0 91.0 91.0 C2 Seasonal Efficiency* Sound Power Level Standard Unit (Radiated) ESP = 80 Pa 2.52 2.52 2.72 2.9 2.78 B B A A A 19.9 24.8 36.1 42.3 50.6 COOLING Cooling Full load performances* Sound Power Level Standard Unit + Option 15 Standard unit (with hydronic module) kg 207 226 253 278 290 Standard unit (without hydronic module) kg 193 213 237 262 273 Refrigerant R-410A Compressor One scroll compressor Control Pro-Dialog+ Fans Two twin-speed centrifugal fans, 5 backward-curved blades Air flow l/s 1640 1640 3472 3472 3472 Evaporator One plate heat exchanger Condenser Copper tubes and aluminium fins Unit with hydronic module pump One single-speed pump, screen filter, expansion tank, flow switch, water circuit drain valve, pressure gauge, automatic air purge valve, safety valve Entering water connection in 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 Leaving water connection in 1 1 1-1/4 1-1/4 1-1/4 Nominal operating current A 1.30 1.4 2.4 2.6 2.8 1002 C1 C2 * † Length mm 1136 1136 1002 1002 Depth mm 584 584 8 24 824 824 Height mm 1608 1608 1829 1829 1829 033 040 AIR TREATMENT Dimensions Cooling mode conditions: Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m2 K/W. Outside air temperature 35°C Cooling mode conditions::Water heat exchanger, entering/leaving temperature 23°C/18°C, fouling factor 0 m2 K/W. Outside air temperature 35°C In accordance with standard EN14511-3:2013 Weight shown is a guideline only. Eurovent certified data Electrical data 30RBY 017 021 026 HEATING HEATING Operating weight† Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% Control circuit supply *** A 75 95 118 118 176 Maximum operating power input** kW 7.8 9.1 11 13.8 17.5 Maximum operating current draw*** A 13 16 20 24 30 Maximum instantaneous start-up current (locked rotor current of the compressor). Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Note: Units 30RB 602-802 have two electrical connection points. C A R R I E R 2 0 1 6 / 2 0 1 7 69 CONTROLS * ** 24 V via internal transformer Maximum start-up current (Un)*