AHI Carrier Catalog | Page 653

HYDRONIC DUCTED FAN COIL UNITS  42NL & 42NH Options Specifications Electric heater (option for 2-pipe coil) Electric heater-resistance wire type ■■ Supply voltage: 230 V - 1 ph - 50 Hz ■■ Heater size and capacity per unit (+5% ; -10%): Electrical Heater Capacity 42NH/NL 2-5 42NH/NL 2-9 42NH/NL 3-5 42NH/NL 3-9 42NH/NL 4-5 42NH/NL 4-9 42NH/NL 5-5 42NH/NL 5-9 42NH 6-5 42NH 6-9 42NH 7-5 42NH 7-9 Low Medium High Very High 1 x 500 W 1 x 500 W 1 x 500 W 1 x 500 W 2 x 500 W 1 x 500 W 2 x 500 W 2 x 500 W 2 x 500 W 2 x 500 W 2 x 500 W 2 x 500 W 1 x 800 W 1 x 800 W 1 x 800 W 1 x 800 W 2 x 800 W 1 x 800 W 2 x 800 W 2 x 800 W 2 x 800 W 2 x 800 W 2 x 800 W 3 x 500 W 1 x 1000 W 1 x 1000 W 1 x 1000 W 1 x 1000 W 2 x 1000 W 1 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W 3 x 800 W NA NA 1 x 1600 W 1 x 1600 W NA 1 x 1600 W NA NA 2 x 1600 W 2 x 1600 W 2 x 1600 W 3 x 1000 W ■■ The heater is protected with a dual safety device: a) Self-holding automatically reset integrated safety thermostat b) Destructive thermofuse link ■■ Available for 2-pipe coil only. WARNING: Minimum air flow must be maintained to avoid damaging the electric heaters. A minimum control signal of 3V is selected by default with Electronic Carrier controller (NTC / WTC). To prevent low airflow with 42NL range, plenum cannot be chosen as an option. Fresh air controller (option) ■■ Constant volume fresh air controller The fan coil can be fitted with a constant fresh air flow controller adjustable from 15 m3/h to 180 m3/h to allow control of the introduction of fresh air and of the air change rate. The fresh air supply can be located in the air supply plenum, in the air return plenum or in the side of the base unit casing for compact design. The fresh air controller may be modified on site by relocating the damper (adjustable screw). Three ranges of air-controller are provided: 15 to 50m3/h, 60 to 100m3/h and 110 to 180m3/h. IMPORTANT: If an optional return air temperature sensor is provided, the constant fresh air flow rate must not exceed 50% of the unit supply air flow rate at minimum speed. ■■ Variable volume fresh air controller The unit can be equipped with an optional variable fresh air flow controller from 0-55 l/s (0-200 m3/h). It is connected to the numeric Carrier controller and can regulate the fresh air intake in two ways: -- Either using a fixed rate set by the installer that can be reconfigured as required -- Or based on the CO2 level; in this case it is connected to a CO2 sensor via the Carrier numeric controller. 1 AIR TREATMENT NOTE: To operate correctly,the fresh air flow controller requires a differential pressure in the range of 60 Pa to 210 Pa. 2 Example: Range 50-100 m3/h 1 2 3 C Air Damp er Fresh airflow damper position setting (in m3/h) Airflow adjustment screw A R R I E R 2 0 1 6 NOTE: With the variable fresh air flow controller the upstream pressure in the fresh air duct must be 180 Pa. / 2 0 1 7 653 CONTROLS 3