AHI Carrier Catalog | Page 651

HYDRONIC DUCTED FAN COIL UNITS  42NL & 42NH Physical and electrical data at Eurovent conditions 42NH - Size 6 and 7 With G1 filter - without plenum 42NH 635 Fan speed R5 (Eurovent certification speeds) Air flow Available static pressure 645 R4 R3 R2 R1 (L) (M) (H) (Max) 397 460 499 R5 200 639 649 R4 R3 R2 R1 2V 6V 7V 10V 2V 7V 8V 10V (L) (M) (H) (Max) (L) (M) (H) (Max) (L) (M) (H) (Max) 298 397 460 499 102 269 303 389 327 364 425 l/s 200 298 m3/h 720 1072 1428 1657 1796 720 1072 1428 1657 1796 368 967 1089 1400 399 1176 1310 1531 Pa 13 28 50 67 79 13 28 50 67 50 63 50 79 7 105 111 6 62 85 Cooling mode, two pipes* Total cooling capacity kW 4.22 6.04 7.55 8.33 8.77 4.77 7.03 8.86 9.79 10.28 2.18 5.52 6.11 7.45 2.45 7.62 8.31 9.29 Sensible cooling capacity kW 3.36 4.85 6.18 6.92 7.36 3.63 5.37 6.90 7.75 8.23 1.74 4.42 4.91 6.08 1.93 5.84 6.42 7.29 Water flow rate l/s 0.20 0.29 0.36 0.40 0.42 0.23 0.34 0.42 0.47 0.49 0.11 0.26 0.29 0.36 0.12 0.36 0.40 0.44 l/h 730 1040 1300 1430 1510 820 1210 1520 1680 1770 380 950 1050 1280 420 1310 1430 1600 Water pressure drop kPa 11 23 24 19 24 28 Water content l 1.5 34 40 44 11 38 44 48 2 3 33 1.5 4 34 40 2 Heating mode, two pipes** Heating capacity kW 6.09 8.83 11.29 12.66 13.40 6.57 9.69 12.45 13.95 14.75 3.14 8.04 8.95 11.11 3.47 10.55 11.59 13.15 Cooling mode, four pipes* Total cooling capacity kW 3.99 5.61 6.87 7.47 7.82 2.09 5.68 6.16 6.78 Sensible cooling capacity kW 3.24 4.63 5.80 6.43 6.80 1.70 4.69 5.12 5.72 Water flow rate l/s 0.19 0.27 0.33 0.36 0.37 0.10 0.27 0.29 0.33 l/h 690 960 1180 1280 1340 360 980 1060 1170 Water pressure drop kPa 10 20 29 3 20 24 29 Water content l 1.3 NA 34 NA 36 1.3 Heating mode, four pipes*** Heating capacity kW 5.67 7.82 9.27 9.88 10.17 2.93 7.90 8.48 9.18 Water flow rate l/s 0.14 0.19 0.23 0.24 0.25 0.07 0.19 0.21 0.23 500 690 810 870 890 260 690 750 810 12 17 19 20 2 13 14 16 NA l/h Water pressure drop kPa 7 Water content l 0.7 Electric heater NA 0.7 230V ±10% - 1ph 230V ±10% - 1ph 230V ±10% - 1ph 230V ±10% - 1ph Maximum capacity W 3200 3200 3200 3200 Current drawn A 14.6 14.6 14.6 14.6 Sound power level (return dB(A) 50 and radiated) 56 58 61 62 50 56 58 61 62 39 62 64 70 39 64 67 70 Sound power level (supply) dB(A) 50 59 62 65 66 50 59 62 65 66 45 58 61 68 45 61 64 68 Power input W 185 217 225 242 286 185 217 225 242 286 9 76 106 222 9 111 153 233 Current drawn A 0.96 1.11 1.28 1.38 1.55 0.96 1.11 1.28 1.38 1.55 0.09 0.71 1.02 2.01 0.09 0.71 1.02 2.01 FCEER [energy class] - 2 pipes 30 [D] 35 [D] 100 [A] 92 [A] FCCOP [energy class] 44 [C] 152 [A] Electrical data, motor 48 [C] 135 [A] FCEER [energy class] - 4 pipes 28 [D] 72 [B] FCCOP [energy class] 38 [D] 107 [A] AIR TREATMENT Sound levels Fan speed: L = Low, M = Medium, H = High * Eurovent conditions: Entering air temperature = 27°C db/47% rh – entering water temperature = 7°C, water temperature difference = 5 K. ** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling. *** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 70°C, water temperature difference = 10 K. CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 651