AHI Carrier Catalog | Page 622

Physical and electrical data Four-pipe coil 42N_, 4-pipe coil S30 Fan speed R1 Fan type Air flow S42 R2 R3 R4 R5 R1 Two, centrifugal S45 R2 R3 R1 S65† R2 R3 R4 R5 R1 R2 R3 Two, centrifugal Two, centrifugal l/s 205 181 152 126 97 267 221 147 332 275 224 184 146 420 Two, centrifugal m3/h 739 651 547 454 349 960 795 530 1195 991 805 663 524 1511 1187 851 330 236 Cooling mode* Total cooling capacity kW Sensible cooling capacity kW Water flow rate 3,2 2,97 2,72 2,41 1,98 3,81 3,41 2,66 4,82 4,28 3,8 3,25 2,69 5,75 4,97 4 2,71 2,49 2,23 1,94 1,57 3,24 2,84 2,14 4,13 3,61 3,13 2,65 2,17 4,88 4,1 3,2 0,19 l/s 0,15 0,14 0,13 0,11 0,09 0,18 0,16 0,13 0,23 0,21 0,18 0,16 0,13 0,28 0,24 l/h 550 510 470 410 340 650 580 460 830 740 650 560 460 990 850 700 m3/h 0,55 0,51 0,47 0,41 0,34 0,65 0,58 0,46 0,83 0,74 0,65 0,56 0,46 0,99 0,85 0,7 11 10 8 5 15 13 8 26 21 17 13 9 36 28 19 Water pressure drop kPa 13 Water content l 1.5 1.5 1.8 1,8 Heating mode** Heating capacity kW 4,16 3,76 3,47 3,18 2,7 5,02 4,43 3,39 6,05 5,58 4,95 4,49 3,86 7,16 6,06 5,07 Water flow rate l/s 0,1 0,09 0,08 0,08 0,07 0,12 0,11 0,08 0,15 0,14 0,12 0,11 0,09 0,18 0,15 0,13 l/h 370 330 300 280 240 440 390 300 530 490 440 390 340 630 530 450 m /h 0,37 0,33 0,3 0,28 0,24 0,44 0,39 0,3 0,53 0,49 0,44 0,39 0,34 0,63 0,53 0,45 Water pressure drop kPa 22 18 16 14 10 31 25 15 46 40 33 27 21 63 47 34 Water content l 0.4 3 0.4 0.5 0.5 Sound levels Sound power level dB(A) 56 51 47 42 36 62 57 47 62 57 55 47 41 68 62 54 Sound pressure level*** dB(A) 47 42 38 33 27 53 48 38 53 48 46 38 32 59 53 45 41 37 33 28 22 48 43 34 48 43 41 34 28 54 49 40 57 50 46 44 42 100 75 45 129 92 83 77 69 165 125 90 0.25 0.23 0.21 0.2 0.19 0.45 0.35 0.21 0.55 0.4 0.37 0.34 0.31 0.7 0.6 0.4 NR Value AIR TREATMENT Electrical data Power input W Current drawn A Eurovent energy class FCEER/FCCOP E/E E/E E/E E/E Connection diameter Cooling in 3/4 gas 3/4 gas 3/4 gas 3/4 gas Heating in 1/2 gas 1/2 gas 1/2 gas 1/2 gas * ** *** † Eurovent conditions: Entering air temperature = 27°C db/19°C wb – entering/leaving water temperature = 7°C/12°C, high fan speed. Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling mode. Based on a hypothetical acoustic attenuation for the room and the air distribution system of -9 dB(A). This unit complies with all applicable standards for EC marking (for further details see Declaration of Conformity). Except the unit size 42N_S65 which is not CE labeled due to fan ­efficiency ­regulation 327/2011 but is fully compliant with Machinery (2006/42/EC) and Electromagnetic Compatibility (2004/108/EC) directives. 622 C A R R I E R 2 0 1 6 / 2 0 1 7