AHI Carrier Catalog | Page 579

HYBRID TERMINAL  36XB Physical data Cooling capacities Room Temperature: Dry bulb = 27°C and humidity = 47% - Fresh air temperature 14°C Chilled water temperature 7-12°C Chilled water temperature 14-17°C LEC Air Fan flow speed m3/h V Total cooling capacity W Sensible cooling capacity W Coil Water flow l/h Water pressure drop KPa Total cooling capacity W Sensible cooling capacity W Coil Water flow l/h Water pressure drop KPa Fan consumption W Air pressure drop Pa Noise Pressure level dB(A)* Noise level NR* 30 269 537 891 1297 753 830 1145 1465 1107 1128 1414 1698 1443 1508 1730 1987 1767 1797 1980 2194 249 416 672 977 609 664 895 1136 902 917 1129 1346 1184 1233 1401 1600 1460 1484 1624 1791 43 68 130 202 83 97 151 205 122 126 173 223 158 169 205 252 191 194 227 263 1 2 4 10 2 2 6 10 4 4 7 12 6 7 10 15 9 9 12 71 256 330 508 719 504 542 703 870 748 759 906 1055 985 1018 1135 1271 1217 1233 1329 1444 252 325 503 714 499 537 697 865 743 754 901 1051 989 1013 1130 1268 1212 1228 1325 1441 36 58 108 169 68 79 126 173 101 104 144 187 130 140 173 212 158 162 191 223 1 1 3 7 1 2 4 7 2 3 5 9 4 5 7 11 6 7 9 12 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 9 10 11 14 28 29 30 32 57 57 59 61 98 98 99 100 149 149 150 151 < 20 < 20 32 44 < 20 < 20 32 44 < 20 < 20 32 44 35 35 35 45 41 41 42 46 < 20 < 20 27 39 < 20 < 20 27 39 < 20 < 20 27 39 30 30 30 40 36 36 37 41 60 90 120 150 0 2 5 8 0 2 5 8 0 3 5 8 0 2 5 8 0 2 5 8 Preliminary Data : * Sound Level guidance with acoustic atenuation -9 dB(A) Heating capacities 30 60 90 120 150 Hot water temperature 45-40°C Total Coil Water heating Water flow pressure capacity l/h drop W KPa Fan consumption W Air pressure drop Pa Noise Pressure level dB(A)* Noise level NR* 0 2 5 8 0 2 5 8 0 3 5 8 0 2 5 8 0 2 5 8 241 390 749 1179 475 551 877 1219 699 722 1021 1327 912 981 1219 1500 1115 1148 1346 1583 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 9 10 11 14 28 29 30 32 57 57 59 61 98 98 99 100 149 149 150 151 < 20 < 20 32 44 < 20 < 20 32 44 < 20 < 20 32 44 35 35 35 45 41 41 42 46 < 20 < 20 27 39 < 20 < 20 27 39 < 20 < 20 27 39 30 30 30 40 36 36 37 41 444 718 1365 2127 873 1009 1593 2195 1275 1316 1849 2383 1654 1777 2195 2684 2013 2070 2416 2829 18 32 61 94 40 43 68 97 58 61 83 104 72 79 97 119 90 94 104 126 1 1 1 2 1 1 1 2 1 1 2 2 1 1 2 3 2 2 3 3 43 68 130 205 83 97 151 212 122 126 176 230 158 169 212 259 194 198 234 274 1 1 4 9 2 1 5 9 3 4 7 11 6 6 9 13 8 8 11 15 Preliminary Data : * Sound Level guidance with acoustic atenuation -9 dB(A) C A R R I E R 2 0 1 6 / 2 0 1 7 579 CONTROLS Air flow m3/h Hot water temperature 70-50°C Total Coil Water LEC heating Water flow pressure Fan drop speed capacity l/h W KPa V AIR TREATMENT Room Temperature: 20°C - Fresh air temperature 20°C