Electrical data
30XWHV
580
630
810
880
1150
1280
1470
1570
1710
Power circuit
Nominal voltage
V-ph-Hz 400-3-50 ± 10%
Control circuit supply
24 V, via internal transformer
Start-up current*
Negligible (lower than maximum current drawn)
Maximum power factor
*
**
***
0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93
Maximum power input, circuit A/B***
kW
155/-
193/-
222/-
246/-
155/155
193/193
222/193
222/222
246/246
Eurovent current draw, circuit A/B**
A
175/-
200/-
240/-
265/-
175/175
200/200
240/200
240/240
265/265
Maximum current draw (Un), circuit
A/B***
A
270/-
330/-
380/-
421/-
270/270
330/330
380/330
380/380
421/421
Instantaneous start-up current.
Eurovent unit operating conditions: evaporator entering/leaving water temperature 12°C/7°C, condenser entering/leaving water temperature 30°C/35°C.
Values obtained at operation with maximum unit power input. Values given on the unit name plate.
HEATING
Options
Options
No.
Description
Advantages
Use 30XWHV
Light-brine solution, down to -3°C
8
Implementation of new algorithms of
control to allow chilled brine solution
production down to -3°C when ethylene
glycol is used (0°C with propylene glycol)
Matches with most application
requirements for ground-sourced heat
pumps and fits with many industrial
processes requirements
580-1710
Master/slave operation
58
Unit equipped with supplementary water
outlet temperature sensor kit to be fieldinstalled allowing master/slave operation
of two units connected in parallel
Optimised operation of two chillers
connected in parallel with operating time
equalisation
580-1710
Single power connection point
81
Unit power connection via one main
supply connection
Quick and easy installation
1150-1710
Evap. pump power/control circuit
84
Unit equipped with an electrical power and Quick and easy installation: the control of
fixed speed pumps is embedded in the
control circuit for one pump evaporator
unit control
side
580-1710
Evaporator dual pumps electrical
power / control circuit
84D
Unit equipped with an electrical power and Quick and easy installation: the control of
fixed speed pumps is embedded in the
control circuit for two pumps evaporator
unit control
side
580-1710
Cond. pump power/control circuit
84R
Unit equipped with an electrical power and Quick and easy installation: the control of
fixed speed pumps is embedded in the
control circuit for one pump condenser
unit control
side
580-1710
Cond. dual pumps power/control
circuit
84T
Unit equipped with an electrical power and Quick and easy installation: the control of
fixed speed pumps is embedded in the
control circuit for two pumps condenser
unit control
side
580-1710
Condenser insulation
86
Thermal condenser insulation
Minimizes thermal dispersions condenser
side (key option for heat pump or
heat recovery applications) and allows
compliancy with special installation criteria
(hot parts insulated)
580-1710
Service valve set
92
Liquid line valve (evaporator inlet) and
compressor suction line valve
Allow isolation of various refrigerant circuit
components for simplified service and
maintenance
580-1710
Evaporator with one pass less
100C
Evaporator with one pass on the water
side. Evaporator