WATER-COOLED SCREW CHILLERS 30XWH 254-1762
852
*
1052
1154
1252
1352
1452
1552
1652
1702
400-3-50
360-440
24 V via the built-in transformer
587
-
414
414
558
414
414
574
414
414
574
587
414
747
587
587
780
587
587
801
587
587
819
587
587
819
587
587
819
587
-
414
414
631
414
414
656
414
414
656
587
414
829
587
587
882
587
587
904
587
587
938
587
587
938
587
587
938
0.90
0.92
0
0.88
0.90
0
0.89
0.91
0
0.89
0.91
0
0.88
0.90
0
0.88
0.90
0
0.89
0.91
0
0.9
0.92
0
0.9
0.92
0
0.9
0.92
0
223
-
150
135
284
151
151
301
151
151
301
184
151
334
184
184
367
200
200
399
223
223
447
223
202
425
223
223
447
232
-
162
144
306
162
162
324
162
162
324
193
162
355
193
193
386
214
214
427
232
232
464
232
214
446
232
232
464
351
-
242
217
459
242
242
484
242
242
484
295
242
537
295
295
590
317
317
634
351
351
702
351
317
668
351
351
702
358
-
260
230
490
260
260
520
2 60
260
520
304
260
564
304
304
608
340
340
680
358
358
716
358
340
698
358
358
716
205
-
133
118
251
133
133
265
133
133
265
173
133
305
173
173
346
183
183
365
207
207
414
207
185
391
207
207
414
325
-
212
191
403
212
212
424
212
212
424
278
212
490
278
278
556
290
290
580
325
325
650
325
290
615
325
325
650
***
****
†
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained
at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C.
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained
at operation with maximum unit power input.
Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C
Values obtained at operation with maximum unit power input.
Values obtained at operation with maximum unit power input. Values given on the unit name plate.
C
A
CONTROLS
**
HEATING
Power circuit
Nominal power supply
V-ph-Hz
Voltage range
V
Control circuit
Nominal start-up current*
Circuit A
A
Circuit B
A
Option 81
A
Maximum start-up current**
Circuit A
A
Circuit B
A
Option 81
A
Cosine phi
Nominal***
Maximum****
Total harmonic distortion****
%
Maximum power input†
Circuit A
kW
Circuit B
kW
Option 81
kW
Nominal current drawn***
Circuit A
A
Circuit B
A
Option 81
A
Maximum current drawn (Un)†
Circuit A
A
Circuit B
A
Option 81
A
Maximum current drawn (Un -10%)****
Circuit A
A
Circuit B
A
Option 81
A
Maximum power input with option 150B†
Circuit A
kW
Circuit B
kW
Option 81
kW
Maximum current drawn (Un) with option 150B†
Circuit A
A
Circuit B
A
Option 81
A
1002
AIR TREATMENT
30XWH-
R
R
I
E
R
2
0
1
6
/
2
0
1
7
541