AHI Carrier Catalog | Page 538
Physical data
HEATING
30XWH-
852
1002
1052
1154
1252
1352
Heating application as per EN14511-3:2013† - standard unit
Condition 2
Nominal heating capacity
kW
967
1138 1190 1320 1384 1481
COP
kW/kW 4.64
4.48
4.42
4.54
4.73
4.57
Eurovent class heating
A
A
B
A
A
A
Heating application †† - standard unit
Condition 2
Nominal heating capacity
kW
964
1134 1186 1314 1380 1476
COP
kW/kW 4.93
4.76
4.74
4.89
5.02
4.88
Sound levels - standard unit
Sound power level*
dB(A)
99
102
102
102
102
102
Sound pressure level at 1 m**
dB(A)
82
84
84
84
83
83
Sound levels - standard unit + option 257***
Sound power level*
dB(A)
96
99
99
99
99
99
Sound pressure level at 1 m**
dB(A)
78
80
80
80
80
80
Dimensions - standard unit
Length
mm
2780 4025 4025 4025 4730 4730
Width
mm
1442 1036 1036 1156 1156 1156
Height
mm
1898 1870 1925 2051 2051 2051
Operating weight****
kg
3492 5370 5408 5698 7066 7267
Compressors
Semi-hermetic 06T screw compressors, 50 r/s
Circuit A
1
1
1
1
1
1
Circuit B
1
1
1
1
1
Refrigerant**** - standard unit
R-134a
Circuit A
kg
140
85
85
105
120
115
Circuit B
kg
85
85
105
120
115
Global Warming Potential (GWP)
tonnes 200
122
122
150
172
164
Tonnes of equivalent CO2 of greatest circuit
Capacity control
Touch Pilot, electronic expansion valves (EXV)
Minimum capcity
%
15
10
10
10
10
10
Evaporator
Multi-pipe flooded type
Water volume
l
98
182
182
205
301
301
Water connections (Victaulic)
in
6
6
6
8
8
8
Drain and vent connections (NPT)
in
3/8
3/8
3/8
3/8
3/8
3/8
Max. water-side operating pressure
kPa
1000 1000 1000 1000 1000 1000
Condenser
Multi-pipe flooded type
Water volume
l
137
193
193
193
340
340
Water connections (Victaulic)
in
8
8
8
8
8
8
Drain and vent connections (NPT)
in
3/8
3/8
3/8
3/8
3/8
3/8
Max. water-side operating pressure
kPa
1000 1000 1000 1000 1000 1000
1452
1552
1652
1702
1612
4.46
-
1717
4.41
-
1891
4.67
-
1969
4.68
-
1606
4.81
1710
4.80
1884
5.10
1962
5.15
102
83
102
83
102
83
102
83
99
80
99
80
99
80
99
80
4730
1156
2051
7305
4730
1156
2051
7337
4790
1902
1515
8681
4790
1902
1515
8699
1
1
1
1
1
1
1
1
110
110
105
105
195
195
195
195
157
150
279
279
10
10
10
10
301
8
3/8
1000
301
8
3/8
1000
354
8
3/8
1000
354
8
3/8
1000
340
8
3/8
1000
340
8
3/8
1000
426
8
3/8
1000
426
8
3/8
1000
†
Eurovent-certified performances in accordance with standard EN14511-3:2013.
† † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input
generated by the water pump to overcome the internal pressure drop in the heat exchanger.
Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W.
Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W.
*
In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1 and certified by Eurovent.
** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
*** Option 257 = Low noise level.
**** Weight shown is guideline only. Please refer to the unit nameplate.
Eurovent certified data
538
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7