AHI Carrier Catalog | Page 537

WATER-COOLED SCREW CHILLERS  30XWH 254-1762 254 304 354 402 452 552 Heating application as per EN14511-3:2013† - standard unit Condition 2 Nominal heating capacity kW 317 358 421 516 529 599 COP kW/kW 4.59 4.57 4.61 4.54 4.59 4.47 Eurovent class heating A A A A A A Heating application †† - standard unit Condition 2 Nominal heating capacity kW 316 357 419 514 527 597 COP kW/kW 4.80 4.78 4.84 4.74 4.79 4.70 Sound levels - standard unit Sound power level* dB(A) 95 95 95 99 99 99 Sound pressure level at 1 m** dB(A) 78 78 78 82 82 82 Sound levels - standard unit + option 257*** Sound power level* dB(A) 96 96 96 Sound pressure level at 1 m** dB(A) 78 78 78 Dimensions - standard unit Length mm 2724 2724 2724 2741 2741 2741 Width mm 928 928 928 936 936 936 Height mm 1567 1567 1567 1692 1692 1692 Operating weight**** kg 2017 2036 2072 2575 2575 2613 Compressors Semi-hermetic 06T screw compressors, 50 r/s Circuit A 1 1 1 1 1 1 Circuit B Refrigerant**** - standard unit Circuit A kg 84 80 78 82 82 82 Circuit B kg Global Warming Potential (GWP) R-134a tonnes 120 114 112 117 117 117 Tonnes of equivalent CO2 of greatest circuit Capacity control Touch Pilot, electronic expansion valves (EXV) Minimum capcity % 15 15 15 15 15 15 Evaporator Multi-pipe flooded type Water volume l 50 56 61 70 70 70 Water connections (Victaulic) in 5 5 5 5 5 5 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 Condenser Multi-pipe flooded type Water volume l 55 55 55 76 76 76 Water connections (Victaulic) in 5 5 5 5 5 5 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 602 652 702 802 632 4.52 A 751 4.56 A 813 4.49 A 887 4.46 A 629 4.78 748 4.78 810 4.73 883 4.73 99 82 99 82 99 82 99 82 96 78 96 78 96 78 96 78 2741 936 1692 2644 3059 1040 1848 3247 3059 1040 1848 3266 3059 1040 1848 3282 1 - 1 - 1 - 1 - 82 - 145 - 140 - 135 - 117 207 200 193 15 15 15 15 70 5 3/8 1000 109 6 3/8 1000 109 6 3/8 1000 109 6 3/8 1000 76 5 3/8 1000 109 6 3/8 1000 109 6 3/8 1000 109 6 3/8 1000 † Eurovent-certified performances in accordance with standard EN14511-3:2013. † † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W. Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W. * In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emissio n values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. ** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). *** Option 257 = Low noise level. **** Weight shown is guideline only. Please refer to the unit nameplate. AIR TREATMENT 30XWH- HEATING Physical data CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 537