AHI Carrier Catalog | Page 515

WATER-SOURCE HEAT PUMPS  61WG 020-090 Physical data 61WG 020 025 030 035 040 045 050 060 070 080 090 Heating Standard Unit H1 Nominal capacity kW 29.0 34.4 38.3 44.2 50.2 57.2 68.6 78.2 88.4 100.1 116.5 Full load performances* H1 COP kW/kW 5.42 5.29 5.21 5.29 5.34 5.32 5.49 5.36 5.46 5.28 5.33 H1 Eurovent class heating A A A A A A A A A A A H2 Nominal capacity kW 21.7 25.7 29.4 34.1 37.7 42.1 50.4 56.7 67.0 74.6 87.0 H2 COP kW/kW 4.24 4.26 4.29 4.27 4.27 4.25 4.25 4.27 4.26 4.28 4.29 H3 Nominal capacity kW 27.7 33.0 36.7 42.7 48.7 54.8 66.4 75.7 84.1 95.3 109.0 H3 COP kW/kW 4.35 4.34 4.20 4.27 4.32 4.36 4.51 4.32 4.35 4.27 4.31 H3 Eurovent class heating B B B B B B A B B B B H4 Nominal capacity kW 26.9 32.0 35.4 41.3 46.5 52.3 63.6 74.0 80.4 90.3 103.0 H4 COP kW/kW 3.65 3.68 3.52 3.59 3.56 3.66 3.75 3.64 3.63 3.56 3.60 H5 Nominal capacity kW 25.7 30.7 33.7 39.6 42.9 49.1 60.6 70.7 76.3 85.0 97.4 H5 COP kW/kW 2.96 2.96 2.86 2.93 2.88 2.96 2.98 3.04 2.99 2.94 2.97 H1 SCOP kW/kW 5.36 5.20 5.11 5.19 5.23 5.19 5.84 5.93 5.93 5.83 5.82 Seasonal efficiency*** H1 Ƞs heat % 206 200 197 200 201 200 226 229 229 225 225 H1 Prated kW 34 41 45 53 60 68 81 93 105 119 139 H4 SCOP kW/kW 4.37 4.32 4.20 4.28 4.32 4.35 4.86 4.88 4.80 4.89 4.80 H4 Ƞs heat % 167 165 160 163 165 166 186 187 184 188 184 H4 Prated kW 32 38 42 49 56 63 76 88 97 109 124 kg 191 200 200 207 212 220 386 392 403 413 441 Operating weight(1) Sound power level, standard unit dB(A) 67.0 68.5 69.0 69.3 70.0 70.1 71.5 72.0 72.0 73.0 73.4 Sound power level with option 258 dB(A) 61.0 62.5 63.0 63.3 64.0 64.1 65.5 66.0 66.0 67.0 67.4 dimensions, standard unit(3) Width mm 600 600 600 600 600 600 880 880 880 880 880 Length mm 1044 1044 1044 1044 1044 1044 1474 1474 1474 1474 1474 Height mm 901 901 901 901 901 901 901 901 901 901 901 Compressors Hermetic scroll 48.3 r/s Quantity 1 1 1 1 1 1 2 2 2 2 2 Number of capacity stages 1 1 1 1 1 1 2 2 2 2 2 100 100 100 100 100 100 50 50 50 50 50 Minimum capacity % HEATING Sound levels(2) Charge, standard unit Charge, unit with option 272 kg 3.5 3.5 3.6 3 .7 4.0 4.6 7.6 7.8 7.9 8.7 11.5 teqCO2 7.2 7.3 7.4 7.6 8.2 9.5 15.9 16.3 16.5 18.2 24 kg 2.7 2.9 2.9 3.0 3.2 3.9 7.2 7.3 7.4 7.6 10.5 teqCO2 5.6 6.0 6.1 6.3 6.7 8.1 14.9 15.2 15.5 15.9 21.9 5.0 8.4 9.2 9.6 10.4 12.5 Capacity control Pro-Dialog+ Evaporator Direct-expansion plate heat exchanger Water volume l Water connections 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 4.2 4.6 5.0 8.4 9.2 9.6 10.4 12.5 Plate heat exchanger l 3.3 3.6 3.6 Victaulic Inlet/outlet in 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Colour code: RAL7035 In accordance with standard EN14511-3:2013 Not in accordance with standard EN14511-3:2013.These performances do not take into account the correction for the proportionnal heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. In accordance with standard EN14825:2013, average climate Heating mode conditions: evaporator entering/leaving water temperature 10 °C/7 °C, condenser entering/leaving water temperature 30 °C/35 °C, evaporator and condenser fouling factor 0 m2 K/W. Heating mode conditions: evaporator entering/leaving water temperature 0 °C/-3 °C, condenser entering/leaving water temperature 30 °C/35 °C, evaporator and condenser fouling factor 0 m2 K/W, evaporator fluid: 30% Heating mode conditions: evaporator entering/leaving water temperature 10 °C/7 °C, condenser entering/leaving water temperature 40 °C/45 °C, evaporator and condenser fouling factor 0 m2 K/W. Heating mode conditions: evaporator entering/leaving water temperature 10 °C/7 °C, condenser entering/leaving water temperature 47 °C/55 °C, evaporator and condenser fouling factor 0 m2 K/W. Heating mode conditions: evaporator entering/leaving water temperature 10 °C/7 °C, condenser entering/leaving water temperature 55 °C/65 °C, evaporator and condenser fouling factor 0 m2 K/W. Weight shown is a guideline only. Please refer to the unit nameplate In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 515 CONTROLS (3) 4.6 in Chassis paint colour H5 (1) (2) 4.2 kPa Water connections H3 H4 3.6 Inlet/outlet Net water volume *** H1 H2 3.6 Max. water-side operating pressure Condenser * ** 3.3 Victaulic AIR TREATMENT Refrigerant(1)