AHI Carrier Catalog | Page 504

Options Options No. Description HEATING Corrosion 3A protection, traditional coils Unit equipped for air 12 discharge ducting Low noise level Grilles and enclosure panels Enclosure panels 15 23 Soft Starter Winter operation down to -20°C Water exchanger frost protection Water exchanger and hydraulic mod. frost protection Partial heat recovery 25 28 Master/slave operation 58 Compressor discharge valves HP single-pump hydronic module 93A 23A 41 42A 49 Fins made of pre-treated aluminium (polyurethane and epoxy) Advantages Utilisation Improved corrosion resistance, recommended for moderate marine and urban environments 30RQM/30RQP 160-520 Unit equipped with high static variable-speed fans (maximum 200 Pa), each fan equipped with a connection flange allowing the connection to the ducting system. Aesthetic and sound absorbing compressor enclosure Metal grilles on the 4 unit sides, plus side enclosure panels at each end of the coil Side enclosure panels at each end of the coil Ducted fan discharge, optimised condensing or evaporating temperature control, based on the operating conditions and system characteristics Noise level reduction by 1 to 2 dB(A) Improves aesthetics, protection against intrusion to the unit interior, coil and piping protection against impacts. Improves aesthetics, coil and piping protection against impacts. Electronic starter on each compressor Reduced start-up current Fan speed control of lead fan for each circuit using a Stable unit operation for outside air temperature from 0°C variable frequency drive down to -20°C in cooling mode Electric heater on the water exchanger and the water piping Water exchanger module frost protection between 0°C and -20°C outside air temperature Electric heater on the evaporator, hydronic module and Water exchanger and hydronic module frost protection optional expansion tank between 0°C and -20°C outside air temperature 30RQM/30RQP 160-520 Unit equipped with one desuperheater on each refrigerant circuit Unit equipped with supplementary water outlet temperature sensor kit to be field-installed allowing master/slave operation of two units connected in parallel Shut-off valve on the compressor discharge piping Production of free high-temperature hot-water simultaneously with hot or chilled water production Optimised operation of two units connected in master/ slave operation with operating time equalisation 30RQM/30RQP 160-520 Simplied maintenance. Possibility to store the refrigerant charge in the condenser side during servicing Easy and fast installation (plug & play) 30RQM/30RQP 160-520 Easy and fast installation (plug & play) 30RQM/30RQP 160-520 Easy and fast installation (plug & play) 30RQM/30RQP 160-520 Easy and fast installation (plug & play) 30RQM/30RQP 160-520 Easy and fast installation (plug & play), significant pumping energy cost savings (more than two-thirds), tighter water flow control, improved sytem reliability 30RQM/30RQP 160-520 Easy and fast installation (plug & play), significant pumping energy cost savings (more than two-thirds), tighter water flow control, improved sytem reliability 30RQM/30RQP 160-520 30RQM/30RQP 160-520 116R Single high-pressure water pump, water filter, electronic water flow control, pressure transducers. For more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. HP dual-pump 116S Dual high-pressure water pump, water filter, electronic hydronic module water flow control, pressure transducers. For more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. LP single-pump 116T Single low-pressure water pump, water filter, electronic hydronic module water flow control, pressure transducers. For more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. LP dual-pump 116U Dual low-pressure water pump, water filter, electronic water hydronic module flow control, pressure transducers. For more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. HP variable-speed 116V Single high-pressure water pump with variable speed drive (VSD), water filter, electronic water flow control, pressure single-pump hydronic module transducers. Multiple possibilities of water flow control. For more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. HP variable-speed 116W Dual high-pressure water pump with variable speed drive (VSD), water filter, electronic flow switch, pressure dual-pump hydronic transducers. Multiple possibilities of water flow control. For module more details, refer to the dedicated chapter (expansion tank not included) Select option 293A for built-in safety hydraulic components. J-Bus gateway 148B Two-directional communication board complying with JBus protocol Lon gateway 148D Two-directional communication board complying with Lon Talk protocol Bacnet over IP 149 Two-directional high-speed communication using BACnet gateway protocol over Ethernet network (IP) 30RQM/30RQP 160-520 30RQM/30RQP 160-520 30RQM/30RQP 160-520 30RQM/30RQP 160-520 30RQM 160-520 30RQM/30RQP 160-520 30RQM/30RQP 160-520 30RQM/30RQP 160-520 30RQM/30RQP 160-520 156 Control board with additional inputs/outputs. See Energy Management Module option chapter Connects the unit by communication bus to a building management system Connects the unit by communication bus to a building management system Easy and high-speed connection by ethernet line to a building management system. Allows access to multiple unit parameters Extended remote control capabilities (Set-point reset, ice storage end, demand limits, boiler on/off command...) 252 Electric heaters under the coils and the condensate pans Prevents frost formation on the coils; compulsory in the 30RQM/30RQP 160-520 Victaulic piping connections with welded joints heating mode,