AIR-TO-WATER HEAT PUMP WITH INTEGRATED HYDRONIC MODULE  30RQM/30RQP 160-520 Electrical data 30RQM 160 380 430 470 520 110 133 147 151 166 191 199 233 266 294 322 Circuits A + B kW 80 0.88 88 0.87 107 0.88 118 0.88 120 0.87 134 0.88 152 0.87 161 0.88 188 0.88 215 0.88 236 0.88 258 0.88 Circuits A + B A 144 158 192 211 215 241 273 289 337 385 422 460 Circuits A + B A 133 146 177 195 199 222 252 266 310 354 390 425 Circuits A + B A 307 356 352 406 409 396 462 440 485 529 600 636 Circuits A + B A 261 283 305 332 336 350 389 394 438 482 527 562 Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C. Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate). Maximum unit operating current at maximum unit power input and 360 V. Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). 30RQP 160 Power circuit Nominal power supply Voltage range Control circuit supply Nominal unit current draw(1) Circuits A + B Maximum unit power input(2) Circuits A + B Cosine phi, unit at max. capacity(2) Maximum unit current draw (Un-10%)(3) Circuits A + B Maximum unit current draw (Un)(4) Circuits A + B Maximum start-up current, standard unit (Un)(5) Circuits A + B Max. start-up current, unit with soft starter (Un)(5) Circuits A + B (1) (2) (3) (4) (5) 210 230 240 270 310 330 380 430 470 520 V-ph-Hz V 400 - 3 -50 360 - 440 24 V via internal transformer A 97 107 130 144 147 162 186 195 227 260 288 316 kW 81 0.88 88 0.88 108 0.88 118 0.88 120 0.88 134 0.88 153 0.88 161 0.88 188 0.88 215 0.88 237 0.88 259 0.88 A 142 154 189 208 211 237 268 284 331 378 416 454 A 131 142 174 192 195 218 247 261 305 348 383 419 A 305 353 349 402 405 392 458 436 479 523 594 629 A 259 279 302 329 332 346 384 389 433 476 520 556 Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C. Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate). Maximum unit operating current at maximum unit power input and 360 V. Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Fan motor electrical data upstream variable frequency drive: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.0 A, start-up current 20 A, power input 1.75 kW. CONTROLS 180 HEATING Fan motor electrical data: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.8 A, start-up current 20 A, power input 1.75 kW. AIR TREATMENT 330 100 Max. start-up current, unit with soft starter (Un)(5) (5) 310 A Maximum start-up current, standard unit (Un)(5) (4) 270 Circuits A + B Maximum unit current draw (Un)(4) (3) 240 400 - 3 -50 360 - 440 24 V via internal transformer Cosine phi, unit at max. capacity (2) Maximum unit current draw (Un-10%)(3) 230 V-ph-Hz V Maximum unit power input(2) (2) 210 Power circuit Nominal power supply Voltage range Control circuit supply Nominal unit current draw(1) (1) 180 C A R R I E R 2 0 1 6 / 2 0 1 7 503