AIR-TO-WATER HEAT PUMP WITH INTEGRATED
HYDRONIC MODULE 30RQM/30RQP 160-520
Electrical data
30RQM
160
380
430
470
520
110
133
147
151
166
191
199
233
266
294
322
Circuits A + B
kW
80
0.88
88
0.87
107
0.88
118
0.88
120
0.87
134
0.88
152
0.87
161
0.88
188
0.88
215
0.88
236
0.88
258
0.88
Circuits A + B
A
144
158
192
211
215
241
273
289
337
385
422
460
Circuits A + B
A
133
146
177
195
199
222
252
266
310
354
390
425
Circuits A + B
A
307
356
352
406
409
396
462
440
485
529
600
636
Circuits A + B
A
261
283
305
332
336
350
389
394
438
482
527
562
Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data
given on the unit nameplate).
Maximum unit operating current at maximum unit power input and 360 V.
Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate).
Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).
30RQP
160
Power circuit
Nominal power supply
Voltage range
Control circuit supply
Nominal unit current draw(1)
Circuits A + B
Maximum unit power input(2)
Circuits A + B
Cosine phi, unit at max. capacity(2)
Maximum unit current draw (Un-10%)(3)
Circuits A + B
Maximum unit current draw (Un)(4)
Circuits A + B
Maximum start-up current, standard unit (Un)(5)
Circuits A + B
Max. start-up current, unit with soft starter (Un)(5)
Circuits A + B
(1)
(2)
(3)
(4)
(5)
210
230
240
270
310
330
380
430
470
520
V-ph-Hz
V
400 - 3 -50
360 - 440
24 V via internal transformer
A
97
107
130
144
147
162
186
195
227
260
288
316
kW
81
0.88
88
0.88
108
0.88
118
0.88
120
0.88
134
0.88
153
0.88
161
0.88
188
0.88
215
0.88
237
0.88
259
0.88
A
142
154
189
208
211
237
268
284
331
378
416
454
A
131
142
174
192
195
218
247
261
305
348
383
419
A
305
353
349
402
405
392
458
436
479
523
594
629
A
259
279
302
329
332
346
384
389
433
476
520
556
Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data
given on the unit nameplate).
Maximum unit operating current at maximum unit power input and 360 V.
Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate).
Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).
Fan motor electrical data upstream variable frequency drive: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.0 A, start-up current 20 A,
power input 1.75 kW.
CONTROLS
180
HEATING
Fan motor electrical data: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.8 A, start-up current 20 A, power input 1.75 kW.
AIR TREATMENT
330
100
Max. start-up current, unit with soft starter (Un)(5)
(5)
310
A
Maximum start-up current, standard unit (Un)(5)
(4)
270
Circuits A + B
Maximum unit current draw (Un)(4)
(3)
240
400 - 3 -50
360 - 440
24 V via internal transformer
Cosine phi, unit at max. capacity (2)
Maximum unit current draw (Un-10%)(3)
230
V-ph-Hz
V
Maximum unit power input(2)
(2)
210
Power circuit
Nominal power supply
Voltage range
Control circuit supply
Nominal unit current draw(1)
(1)
180
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
503