AHI Carrier Catalog | Page 501

AIR-TO-WATER HEAT PUMP WITH INTEGRATED HYDRONIC MODULE  30RQM/30RQP 160-520 Physical data 30RQP 160 180 210 230 240 270 310 330 380 430 470 520 Cooling Standard unit C1 Nominal capacity kW 156 170 203 228 236 268 301 326 376 424 459 511 Full load performances* C1 EER kW/kW 2.80 2.91 2.76 2.79 2.93 2.91 2.90 2.91 2.9 2.9 2.75 2.74 Full load performances*** C1 C1 C1 Eurovent class cooling Gross nominal capacity Gross EER ESEER Gross ESEER kW kW/kW kW/kW kW/kW C 157 2.84 4.05 4.17 B 171 2.95 4.09 4.23 C 204 2.80 4.10 4.28 C 229 2.82 4.14 4.29 B 236 2.96 4.14 4.25 B 269 2.91 4.14 4.28 B 302 2.92 4.19 4.31 B 327 2.93 4.19 4.30 B 377 2.90 4.27 4.40 B 425 2.90 4.28 4.43 C 460 2.78 4.26 4.42 C 512 2.77 4.20 4.36 H1 H1 H1 H2 H2 H2 H1 H1 H2 H2 H1 H1 H1 Nominal capacity COP Eurovent class heating Nominal capacity COP Eurovent class heating Gross nominal capacity Gross COP Gross nominal capacity Gross COP SCOP Ƞs heat Prated kW kW/kW kW kW/kW kW/kW % kW 179 3.69 D 173 2.94 C 179 3.72 172 2.96 3.24 127 127 196 3.73 D 189 3.00 B 195 3.74 188 3.00 3.26 127 141 238 3.75 C 230 3.00 B 237 3.79 229 3.02 3.26 128 167 213 3.51 E 242 2.87 C 213 3.54 242 2.89 3.31 129 177 270 3.81 C 259 3.08 B 269 3.84 259 3.09 3.31 129 169 290 3.70 D 279 2.92 C 290 3.73 278 2.93 3.29 129 204 339 3.69 D 326 2.95 C 338 3.72 325 2.96 3.27 128 224 355 3.77 C 342 3.00 B 354 3.76 341 2.99 3.32 130 244 411 3.68 D 396 2.92 C 410 3.70 395 2.94 3.33 130 283 473 3.72 D 456 2.97 C 472 3.75 454 2.98 3.42 134 325 456 3.62 D 498 2.94 C 455 3.65 497 2.96 3.43 134 361 434 3.57 E 537 2.94 C 432 3.60 535 2.95 3.38 132 379 dB(A) dB(A) 90 58 91 59 91 59 91 59 92 60 92 60 93 61 93 61 94 62 94 62 94 62 94 62 dB(A) dB(A) 89 57 90 58 90 58 90 58 91 59 91 59 91 59 92 60 92 60 93 61 93 61 93 61 mm mm mm 2410 2253 2297 2410 2253 2297 2410 2253 2297 2410 2253 2297 3604 2253 2297 3604 2253 2297 3604 2253 2297 3604 2253 2297 4797 2253 2297 4797 2253 2297 4797 2253 2297 4797 2253 2297 kg kg kg 1462 1542 1670 1693 2105 2252 1545 1624 1778 1801 2213 2378 1640 1720 1860 1882 2304 2500 Hermetic scroll 48.3 tr/s 1 1 2 2 2 2 2 2 2 2 2 3 3 3 4 4 4 5 R410A 14.5 22.0 23.0 24.0 27.0 27.0 30.3 45.9 48.0 50.1 56.4 56.4 23.0 23.0 23.0 24.0 35.0 36.0 48.0 48.0 48.0 50.1 73.1 75.2 Touch Pilot Control 33% 33% 25% 25% 25% 20% Grooved copper tubes and aluminium fins 2378 2504 2632 2608 2752 2849 3076 3239 3318 3347 3527 3629 3359 3539 3677 3408 3588 3726 2 3 5 2 4 6 3 4 7 4 4 8 4 4 8 4 4 8 30.0 62.6 48.5 101.3 33.0 68.9 53.0 110.7 42.0 87.7 53.0 110.7 53.0 110.7 53.0 110.7 54.0 112.8 54.0 112.8 56.0 116.9 56.0 116.9 20% 17% 14% 13% 13% 13% Seasonal efficiency* Seasonal efficiency*** Seasonal efficiency** Sound levels Standard unit Sound power level(1) Sound pressure level at 10 m (2) Standard unit + option 15 (3) Sound power level (1) Sound pressure level at 10 m (2) Dimensions Length Width Height Operating Weight (4) Standard unit Standard unit + option 15 (4) Standard unit + option 15 + option 116S (4) Compressors Circuit A Circuit B No. of control stages Refrigerant Circuit A charge (4) kg tCO2eq kg tCO2eq Circuit B charge (4) Capacity control Minimum capacity Air heat exchangers * ** *** C1 H1 H2 (1) (2) (3) (4) kW kW/kW % In accordance with standard EN14511-3:2013. In accordance with standard EN14825:2013, average climate Not in accordance with standard EN14511-3:2013 Cooling mode conditions: Evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. In dB ref 20 µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). For information, calculated from the sound power level Lw(A). Options: 15 = Low noise level, 116S = High Pressure dual-pump hydronic module Weights are guidelines only. Refer to the unit nameplate. AIR TREATMENT Full load performances*** kW kW/kW HEATING Heating Standard unit Full load performances* CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 501