AHI Carrier Catalog | Page 499

AIR-TO-WATER HEAT PUMP WITH INTEGRATED HYDRONIC MODULE  30RQM/30RQP 160-520 Physical data 30RQM 160 180 210 230 240 270 310 330 380 430 470 520 Cooling Standard unit C1 Nominal capacity kW 156 170 203 228 236 268 301 326 376 424 459 511 Full load performances* C1 EER kW/kW 2.80 2.91 2.76 2.79 2.93 2.91 2.90 2.91 2.9 2.9 2.75 2.74 Full load performances*** C1 C1 C1 Eurovent class cooling Gross nominal capacity Gross EER ESEER Gross ESEER kW kW/kW kW/kW kW/kW C 157 2.84 3.85 3.96 B 171 2.95 3.87 4.00 C 204 2.80 3.90 4.06 C 229 2.82 3.96 4.10 B 236 2.96 3.89 3.99 B 269 2.91 3.96 4.08 B 302 2.92 4.01 4.11 B 327 2.93 4.02 4.11 B 377 2.90 4.05 4.15 B 425 2.90 4.06 4.18 C 460 2.78 4.05 4.19 C 512 2.77 4.02 4.15 H1 H1 H1 H2 H2 H2 H1 H1 H2 H2 H1 H1 H1 Nominal capacity COP Eurovent class heating Nominal capacity COP Eurovent class heating Gross nominal capacity Gross COP Gross nominal capacity Gross COP SCOP Ƞs heat Prated kW kW/kW kW kW/kW kW/kW % kW 179 3.69 D 173 2.94 C 179 3.72 172 2.96 3.07 120 127 196 3.73 D 189 2.98 B 195 3.74 188 3.00 3.12 122 141 238 3.75 C 230 3.00 B 237 3.79 229 3.02 3.1 1 121 167 213 3.51 E 242 2.87 C 213 3.54 242 2.89 3.13 122 177 270 3.82 C 259 3.08 B 269 3.84 259 3.09 3.14 123 169 290 3.70 D 279 2.92 C 290 3.73 278 2.93 3.13 122 204 339 3.69 D 326 2.95 C 338 3.72 325 2.96 3.09 120 224 355 3.77 C 342 3.0 B 354 3.76 341 2.99 3.13 122 244 411 3.68 D 396 2.93 C 410 3.70 395 2.94 3.20 125 283 473 3.72 D 456 2.97 C 472 3.75 454 2.98 3.31 129 325 456 3.62 D 498 2.95 C 455 3.65 497 2.96 3.32 130 361 434 3.57 E 537 2.94 C 432 3.60 535 2.95 3.29 129 379 dB(A) dB(A) 90 58 91 59 91 59 91 59 92 60 92 60 93 61 93 61 94 62 94 62 94 62 94 62 dB(A) dB(A) 89 57 90 58 90 58 90 58 91 59 91 59 91 59 92 60 92 60 93 61 93 61 93 61 mm mm mm 2410 2253 2297 2410 2253 2297 2410 2253 2297 2410 2253 2297 3604 2253 2297 3604 2253 2297 3604 2253 2297 3604 2253 2297 4797 2253 2297 4797 2253 2297 4797 2253 2297 4797 2253 2297 kg kg kg 1426 1505 1633 1656 2068 2216 1509 1588 1741 1764 2176 2342 1605 1683 1824 1846 2267 2463 Hermetic scroll 48.3 tr/s 1 1 2 2 2 2 2 2 2 2 2 3 3 3 4 4 4 5 R410A 14.5 22.0 23.0 24.0 27.0 27.0 30.3 45.9 48.0 50.1 56.4 56.4 23.0 23.0 23.0 24.0 35.0 36.0 48.0 48.0 48.0 50.1 73.1 75.2 Touch Pilot Control 33% 33% 25% 25% 25% 20% Grooved copper tubes and aluminium fins 2341 2467 2596 2572 2716 2813 3040 3202 3281 3289 3470 3571 3302 3482 3620 3342 3522 3660 2 3 5 2 4 6 3 4 7 4 4 8 4 4 8 4 4 8 30.0 62.6 48.5 101.3 33.0 68.9 53.0 110.7 42.0 87.7 53.0 110.7 53.0 110.7 53.0 110.7 54.0 112.8 54.0 112.8 56.0 116.9 56.0 116.9 20% 17% 14% 13% 13% 13% Seasonal efficiency* Seasonal efficiency*** Seasonal efficiency** Sound levels Standard unit Sound power level(1) Sound pressure level at 10 m (2) Standard unit + option 15 (3) Sound power level (1) Sound pressure level at 10 m (2) Dimensions Length Width Height Operating Weight (4) Standard unit Standard unit + option 15 (4) Standard unit + option 15 + option 116S (4) Compressors Circuit A Circuit B No. of control stages Refrigerant Circuit A charge (4) kg tCO2eq kg tCO2eq Circuit B charge (4) Capacity control Minimum capacity Air heat exchangers * ** *** C1 H1 H2 (1) (2) (3) (4) kW kW/kW % In accordance with standard EN14511-3:2013. In accordance with standard EN14825:2013, average climate Not in accordance with standard EN14511-3:2013 Cooling mode conditions: Evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. In dB ref 20 µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). For information, calculated from the sound power level Lw(A). Options: 15 = Low noise level, 116S = High Pressure dual-pump hydronic module Weights are guidelines only. Refer to the unit nameplate. AIR TREATMENT Full load performances*** kW kW/kW HEATING Heating Standard unit Full load performances* CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 499