No.
Description
Advantages
Use 30RQSY
LP dual-pump hydronic module
116G
Dual low-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
Easy and fast installation, operating safety
30RQS/RQSY
039-160
HP variable-speed single-pump
hydronic module
116J
Single high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
Easy and fast installation, reduced power
consumption of the water circulation pump
30RQS/RQSY
039-160
HP variable-speed dual-pump
hydronic module
116K
Dual high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
Easy and fast installation, operating safety,
reduced power consumption of the water
circulation pump
30RQS/RQSY
039-160
HP single-pump hydronic module
without expansion tank
116R
Single high-pressure water pump, water
filter, temperature and pressure sensors. See
hydronic module option.
Easy and fast installation
30RQS/RQSY
039-160
HP dual-pump hydronic module
without expansion tank
116S
Dual high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
Easy and fast installation, operating safety
30RQS/RQSY
039-160
LP single-pump hydronic module
116T
Single low-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
Easy and fast installation
30RQS/RQSY
039-160
LP dual-pump hydronic module
116U
Dual low-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
Easy and fast installation, operating safety
30RQS/RQSY
039-160
HP variable-speed single-pump
hydronic module
116V
Single high-pressure water pump, water
filter, temperature and pressure sensors. See
hydronic module option.
Easy and fast installation, reduced power
consumption of the water circulation pump
30RQS/RQSY
039-160
HP variable-speed dual-pump
hydronic module
116W
Dual high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
Easy and fast installation, operating safety,
reduced power consumption of the water
circulation pump
30RQS/RQSY
039-160
JBus gateway
14 8B
Two-directional communications board,
complies with JBus protocol
Easy connection by communication bus to a
building management system
30RQS/RQSY
039-160
Bacnet gateway
148C
Two-directional communications board,
complies with Bacnet protocol
Easy connection by communication bus to a
building management system
30RQS/RQSY
039-160
LonTalk gateway
148D
Two-directional communications board,
complies with Lon Talk protocol
Easy connection by communication bus to a
building management system
30RQS/RQSY
039-160
Water heat exchanger screw
connection sleeves
264
Inlet/outlet screw connection sleeves
Permit connection of the unit to a screw
connection
30RQS/RQSY
039-160
Welded evaporator water
connection kit
266
Victaulic piping connections with welded
joints
Permit connection of the unit to a connection
other than a Victaulic connection
30RQS/RQSY
039-160
Reinforced ECM filtration for fan
VFD***
282A
Fan variable frequency drive compliance to
IEC 61800-3 C1 class
Allows unit installation in domestic residential
environment by reducing electromagnetic
interferences
30RBSY/RQSY
039-160
Reinforced ECM filtration for pump
VFD****
282B
Pump variable frequency drive compliance to
IEC 61800-3 C1 class
Allows unit installation in domestic residential
environment by reducing electromagnetic
interferences
30RBSY/RQSY
039-160
*
**
30RQS/RQSY 039-160 with option 49 or 30RQS 0039-160 with option 6B.
Winter operation option: This option allows operation of the unit down to -20°C outside air temperature due to the optimised control of the condensing temperature. One fan is equipped
with a frequency converter.
*** 30RQSY 039-160 with option 5B or 6B or 28
**** 30RQSY 039-160 with option 116 J or K or V or W
Partial heat reclaim using desuperheaters (option 49)
A plate heat exchanger is installed in series with the air
condenser coils on the compressor discharge line of each
circuit.
CONTROLS
This option permits the production of free hot water using
heat reclaim by desuperheating the compressor discharge
gases. The option is available for the whole RQSY range, that
are equipped with traditional Cu/Al coils.
AIR TREATMENT
Options
HEATING
DUCTABLE AIR-TO-WATER HEAT PUMPS 30RQSY 039-160
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
483