AHI Carrier Catalog | Page 470

Brine Options (option 5B & option 6B) Operating range with 45% ethylene glycol Operating range with 45% ethylene glycol This option allows production of brine down to 0°C (option 5B) / -15°C (option 6B). The unit is equipped with suction pipe insulation (option 6B only) and a fan frequency converter. 55 45 Outside temperature, Outsideair air temperature, °C °C Note: With options 5B & 6B the units are equipped with ­traditional coils (Cu/Al). The operating range is a function of the suction pressure, which in turn is a function of: -- The brine type -- The brine concentration -- The flow rate -- The brine temperature -- The condensing pressure (ambient temperature). 35 25 15 5 -5 -15 -25 -20 -15 -10 -5 0 5 10 Evaporator leaving water temperature, °C Evaporator leaving water temperature, °C Option 5B Option 5B Option Option 6B6B HEATING Partial heat reclaim using desuperheaters (option 49) This option permits the production of free hot water using heat reclaim by desuperheating the compressor discharge gases. The option is available for the whole RQS range, that are ­equipped with traditional Cu/Al coils. A plate heat exchanger is installed in series with the air ­condenser coils on the compressor discharge line of each circuit. Physical data, 30RQS units with partial heat reclaim using desuperheaters (option 49) 30RQS partial heat reclaim mode Operating weight units with RTPF coils* Standard unit without hydronic module Standard unit with hydronic module option Single high-pressure pump Dual high-pressure pump Refrigerant charge, units with RTPF coils Circuit A Circuit B Condensers Desuperheaters on circuits A and B Water volume, circuit A Water volume, circuit B Max. water-side operating pressure without hydronic module Water connections Connections Outside diameter * 039 045 050 060 070 078 080 090 100 120 140 160 kg 515 522 548 561 562 569 762 909 917 973 1088 1106 kg kg 599 625 792 818 941 986 949 994 1009 1057 1127 1164 1145 1155 16.5 - 21.5 - 27.5 - 28.5 - 33.0 - 19.0 19.0 18.5 18.5 l l kPa 544 552 578 591 591 570 578 603 617 617 R-410A 12.5 13.5 16.5 17.5 18.0 Grooved copper tubes. aluminium fins Plate heat exchangers 0.549 0.549 0.549 0.732 0.732 1000 1000 1000 1000 1000 0.732 1000 0.732 1000 0.976 1000 0.976 1000 0.976 1000 0.732 0.732 1000 0.732 0.732 1000 in mm Cylindrical, male gas thread 1 1 1 1 42 42 42 42 1 42 1 42 1 42 1 42 1 42 1 42 1 34 kg kg 1 42 Weights shown are a guideline only. Operating limits Desuperheater Entering water temperature at start-up Leaving water temperature during operation °C °C Air condenser Outside air temperature °C Minimum Maximum 25* 30 60 65 Minimum Maximum -10 46 * The entering water temperature at start-up must not be lower than 25°C. For installations with a lower temperature a three-way valve is necessary. 470 C A R R I E R 2 0 1 6 / 2 0 1 7