AHI Carrier Catalog | Page 469

No. Description HP dual-pump hydronic module 116C Dual high-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. LP single-pump hydronic 116F Single low-pressure water pump, water module filter, expansion tank, temperature and pressure sensors. See hydronic module option. LP dual-pump hydronic 116G Dual low-pressure water pump, water module filter, expansion tank, temperature and pressure sensors. See hydronic module option. HP variable-speed single-pump 116J Single high-pressure water pump, water hydronic module filter, expansion tank, temperature and pressure sensors. See hydronic module option. HP variable-speed dual-pump 116K Dual high-pressure water pump, water hydronic module filter, expansion tank, temperature and pressure sensors. See hydronic module option. HP single-pump hydronic 116R Single high-pressure water pump, module without expansion tank water filter, temperature and pressure sensors. See hydronic module option. HP dual-pump hydronic 116S Dual high-pressure water pump, module without expansion tank water filter, temperature and pressure sensors. See hydronic module option. LP single-pump hydronic 116T Single low-pressure water pump, module water filter, temperature and pressure sensors. See hydronic module option. LP dual-pump hydronic 116U Dual low-pressure water pump, module water filter, temperature and pressure sensors. See hydronic module option. High-pressure variable-speed 116V Single high-pressure water pump, single-pump hydronic module water filter, temperature and pressure sensors. See hydronic module option. HP variable-speed dual-pump 116W Dual high-pressure water pump, hydronic module water filter, temperature and pressure sensors. See hydronic module option. JBus gateway 148B Two-directional communications board, complies with JBus protocol Bacnet gateway 148C Two-directional communications board, complies with Bacnet protocol LonTalk gateway 148D Two-directional communications board, complies with Lon Talk protocol Inlet/outlet screw connection sleeves Water heat exchanger screw 264 connection sleeves Welded evaporator water 266 Victaulic piping connections with connection kit welded joints * ** Reinforced ECM filtration for fan VFD*** 282A Fan variable frequency drive compliance to IEC 61800-3  C1 class Reinforced ECM filtration for pump VFD**** 282B Pump variable frequency drive compliance to IEC 61800-3  C1 class Advantages Use 30RQS Easy and fast installation, operating safety RQS 039-160 Easy and fast installation RQS 039-160 Easy and fast installation, operating safety RQS 039-160 Easy and fast installation, reduced power consumption of the water circulation pump RQS 039-160 Easy and fast installation, operating safety, reduced power consumption of the water circulation pump RQS 039-160 Easy and fast installation RQS 039-160 Easy and fast installation, operating safety RQS 039-160 Easy and fast installation RQS 039-160 Easy and fast installation, operating safety RQS 039-160 Easy and fast installation, reduced power consumption of the water circulation pump Easy and fast installation, operating safety, reduced power consumption of the water circulation pump Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Permit connection of the unit to a screw connection Permit connection of the unit to a connection other than a Victaulic connection Allows unit installation in domestic residential environment by reducing electromagnetic interferences Allows unit installation in domestic residential environment by reducing electromagnetic interferences RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 RQS 039-160 with option 49 or 30RBS 0039-160 with option 6B. Winter operation option: This option allows operation of the unit down to -20°C outside air temperature due to the optimised control of the condensing temperature. One fan is equipped with a frequency converter. CONTROLS *** RQS 039-160 with option 5B or 6B or 28 **** RQS 039-160 with option 116 J or K or V or W C AIR TREATMENT Options HEATING REVERSIBLE AIR-TO-WATER HEAT PUMPS  30RQS 039-160 A R R I E R 2 0 1 6 / 2 0 1 7 469