Electrical data
30RQS without hydronic module
039
045
050
060
070
078
080
090
100
120
140
160
Power circuit
Nominal power supply
V-ph-Hz
Control circuit supply
400-3-50 ± 10%
24 V via internal transformer
Maximum start-up current (Un)*
*
**
***
Standard unit
A
113.8
134.8
142.8
145.8
176.0
213.0
213.6
173.6
207.6
247.6
243.0
286.0
Unit with electronic starter
option
A
74.7
86.5
93.8
96.2
114.4
139.8
139.8
-
-
-
-
-
Maximum operating
power input**
kW
19.5
22.3
24.5
27.9
31.2
35.8
35.6
42.3
45.6
52.5
62.4
71.6
Nominal unit operating
current draw***
A
25.6
29.0
33.0
36.0
42.4
52.8
53.4
55.4
61.7
77.3
84.8
105.6
Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest
compressor).
Power input, compressors and fans, at the unit operating limits (saturated suction temp. 10°C, saturated condensing temp. 65°C) and nominal voltage of 400 V (data given on the unit
nameplate).
Standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C.
HEATING
Options
Options
No.
Condenser with pre-treated
fins
Low temperature glycol
solution
3A
Very low temperature glycol
solution
Very low noise level
Description
Fins made of pre-treated aluminium
(polyurethane and epoxy)
5B
Low temperature chilled water
production down
to 0°C with ethylene glycol and
propylene glycol. Note: With option 5B
the units are equipped with traditional
coils (Cu/Al).
6B
Low temperature chilled water
production down to -15°C with ethylene
glycol and -12°C with propylene glycol.
Note: With option 6B the units are
equipped with traditional coils (Cu/Al).
15LS Acoustic compressor enclosure and
low-speed fans
25
Electronic compressor starter
28
Fan speed control via frequency
converter
Advantages
Use 30RQS
Improved corrosion resistance,
RQS 039-160*
recommended for marine environments
Covers specific applications down to
RQS 039-160
0°C
Covers specific applications such as ice RQS 039-160
storage and industrial processes
Noise emission reduction at reduced
fan speed
Soft starter
Reduced compressor start-up current
Winter operation**
Stable unit operation when the air
temperature is between
-10°C and -20°C
Frost protection down to -20°C 42
Electric heater on the hydronic module Hydronic module frost protection at low
outside temperatures
Partial heat reclaim
49
Partial heat reclaim by desuperheating Free high-temperature hot-water
of the compressor discharge gas. Note: production simultaneously with chilled
With option 49 the units are equipped
and hot-water production
with traditional coils (Cu/Al).
Master/slave operation
58
Unit equipped with an additional fieldOperation of two units connected in
installed leaving water temperature
parallel with operating time equalisation
sensor, allowing master/slave operation
of two units connected in parallel
Main disconnect switch without 70
Factory-installed main electric
Ease-of-installation and compliance
fuse
disconnect switch in the control box
with local electrical regulations
HP single-pump hydronic
116B Single high-pressure water pump, water Easy and fast installation
module
filter, expansion tank, temperature and
pressure sensors. See hydronic module
option.