AIR-TO-WATER HEAT PUMPS 30RQV 017-021 Environmental care Superior reliability ■■ Non ozone depleting R410A refrigerant -- Chlorine-free refrigerant of the HFC group with zero ozone depletion potential -- Very efficient - gives an increased energy efficiency ratio (EER) ■■ Leak-tight refrigerant circuit -- Brazed refrigerant connections for increased leaktightness -- Verification of pressure transducers and temperature sensors without transferring refrigerant charge ■■ State-of-the-art concept -- Cooperation with specialist laboratories and use of limit simulation tools (finite element calculations) for the design of the critical components, e.g. motor supports, suction/discharge piping etc. ■■ Auto-adaptive control -- Control algorithm prevents excessive compressor cycling and permits reduction of the water quantity in the hydronic circuit (Carrier patent) ■■ Exceptional endurance tests -- Corrosion resistance tests in salt mist in the laboratory -- Accelerated ageing test on components that are submitted to continuous operation: compressor piping, fan supports -- Transport simulation test in the laboratory on a vibrating table. Controls ■■ Choice of control product -- 3 options are available to drive the 30RQV 17-21: • Dry contact • User interface WUI • ModBus protocol HEATING User Interface WUI ■■ Ease-of-use -- NHC control can be associated with a new User interface (WUI) which allow an easy access to the configuration parameters (frequency compressor, refrigerant circuit temperature, sets points, air temp, entering water temp, alarm report…) Occupancy Schedule Mode Down Up -- This user interface is also very intuitive in its use. It allows reading and easy selection of the operating mode. The functions are represented by icons on the LCD backlit screen. -- To facilitate the use of this interface, 3 levels of access are available: end user, installer and factory. ■■ Key features -- Heating and cooling mode -- Domestic hot water -- Master/slave control of 4 units operating in parallel with operating time equalisation and automatic changeover in case of a unit fault (need Master slave sensor in accessory). -- Scheduling period C A R R I E R 2 0 1 6 / 2 0 1 7 -- This interface can be installed up to 50 m away. It is connected to the NHC board with a 4 wires cable. -- 2 installation possibilities: • Inside the room (with remote interface accessory) : IAT sensor is an accessory, it is not mandatory to operate in remote user interface, because WUI has an internal sensor to measure the room temperature take with the internal sensor, setpoint selected is air temperature. • On the HP/chiller (with local user interface option): setpoint is on water temperature are water temperature AIR TREATMENT NHC control associate with compressor and fan variable frequency driver combines intelligence with operating simplicity. The control constantly monitors all machine parameters and precisely manages the operation of compressor, expansion devices, fans and of the water heat exchanger water pump for optimum energy efficiency. ■■ ModBus Direct acces with Modbus connection to set, configure and monitor the 30RQV ■■ Input remote contact : -- Remote On/Off Contact -- Remote Heat/Cool Contact: This switch is used to select the Cooling Mode (contact opened) or the Heating Mode (contact closed). -- Remote Economic Contact: This switch is used to select the regular Home Mode when contact is opened or the Economic Away Mode when contact is closed. 427 CONTROLS NHC Control