AHI Carrier Catalog | Page 423

AIR-TO-WATER HEAT PUMPS 30RQV 017-021 Physical data 30RQV 17 21 14,9 3,0 18,6 3,1 B 20,2 3,8 A 4,01 A 25,8 3,8 A 3,85 17,1 4,1 A 16,9 3,3 A 21,1 4,1 A 20,0 3,3 A Cooling Standard unit Full load performances* C1 C1 Nominal capacity EER C1 C2 C2 C2 Eurovent class cooling Nominal capacity EER Eurovent class cooling ESEER Seasonal efficiency kW kW/kW kW kW/kW kW/kW Nominal capacity COP Eurovent class heating Nominal capacity COP Eurovent class heating kW kW/kW H3 H3 H3 H3 H3 H3 H3 Nominal capacity COP SCOP Ƞs heat Prated Annual Energy consumption Energy class kW kW/kW kW/kW % kW KWh 15,2 2,7 3,1 121 9,5 6269 A+ 21,1 2,5 2,9 113 15,43 10980 A+ dB(A) dB(A) 71 40 74 43 mm mm mm 1109 584 1579 1109 584 1579 kg Rotary compressor R410A kg 190,9 1 199,4 1 8 8 Sound levels Standard unit Sound power level (2) Sound pressure level at 10 m (3) Dimensions - Standard unit Length (5) Width Height Operating Weight (1) Standard unit Compressors Refrigerant Charge (1) Capacity control Minimum capacity (6) Air heat exchanger Fans - Standard unit Quantity Maximum total air flow Maximum rotational speed kW kW/kW % 33% Grooved copper tubes, aluminium fins Axial type fan 2 l/s 2000 rps 14 41% 2 2400 16 Water heat exchanger Water volume Max water-side operating pressure without hydronic module Hydronic module (option) Brazed plate heat exchanger l 1,52 1,9 kPa 1000 1000 Pump, relief valve, paddle flow switch, expansion tank (option) Pump Expansion tank volume Max. water-side operating pressure with hydronic module (4) Water connections (Without Hydronic Module) Inlet diameter (BSP GAS) Outlet diameter (BSP GAS) Water connections (With Hydronic Module) Inlet diameter (BSP GAS) Outlet diameter (BSP GAS) Water Filling System (Option 287) Diameter (BSP GAS) Chassis paint colour Centrifugal pump (fixed speed or variable speed) l 8 8 kPa 300 300 inch inch 1 1 1 1 inch inch 1-1/4 1 1-1/4 1 inch Colour code: 1/2 RAL 7035 1/2 RAL 7035 AIR TREATMENT Seasonal efficiency** H1 H1 H1 H2 H2 H2 * ** C1 C2 H1 H2 H3 (1) (2) In accordance with standard EN 14511-3:2013 In accordance with standard EN 14825:2013, Average climate Cooling mode conditions : evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W Cooling mode conditions : evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W Heating mode conditions : Water heat exchanger water entering/leaving temperature 30°C/35°C, fooling factor 0m² K/W. Outside air temperature 7°C db / 6°C wb Heating mode conditions : Water heat exchanger water entering/leaving temperature 40°C/45°C, fooling factor 0m² K/W. Outside air temperature 7°C db / 6°C wb Heating mode conditions : Water heat exchanger water entering/leaving temperature 47°C/55°C, fooling factor 0m² K/W. Outside air temperature 7°C db / 6°C wb Values are guidelines only. Refer to the unit nameplate. In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. (3) In dB ref 20 μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). (4) Min. water-side operating pressure with fixed speed hydronic module is 50 kPa and with variable speed hydronic module is 40 kPa. (5) Length = 1141 mm if main disconnect switch (6) Cooling Eurovent condition C A R R I E R 2 0 1 6 / 2 0 1 7 423 CONTROLS Standard unit Full load performances* HEATING Heating