HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMPS  61AF 014-019 Physical data 61AF 014-7 014-9 019-9 kW kW/kW 14.1 3,34 kW kW/kW 13.9 3,90 kW kW/kW kW kW/kW kW kW/kW kW kW/kW kW kW/kW kW kW/kW kW/kW % kW 14,2 2,93 14,0 2,44 14,0 3,38 13,8 3,96 14,1 2,94 14,0 2,44 2,72 106 14 A+ 3,13 122 14 A 13.7 3,52 A 13.5 4,17 A 13,8 3,03 13,7 2,50 13,6 3,56 13,5 4,24 13,8 3,04 13,6 2,50 2,84 111 14 A+ 3,32 130 14 A+ 19.8 3,49 A 20.2 4,28 A 19,8 2,96 20,1 2,43 19,7 3,54 20,1 4,36 19,7 2,98 20,0 2,44 2,84 111 19 A+ 3,22 126 18 A+ kg kg 159 169 159 169 206 216 dB(A) dB(A) 71 40 71 40 72 41 mm mm mm l 1103 1103 1135 333 333 559 1278 1278 1579 One, hermetic scroll, 48.3 r/s, one capacity stage R-407C 4.0 4.0 8.0 7,1 7,1 14,2 Pro-Dialog+ 100 100 100 Direct-expansion plate heat exchanger 3.7 3.7 3.9 kPa 300 * ** *** H1 H2 H3 H4 (1) (2) (3) C kg teqCO2 % l/s r/s Connections inch Outside diameter Chassis paint colour mm 300 400 Two, axial twin-speed fans 2050 2050 2000 11.7 11.7 14.5 Grooved copper tubes and aluminium fins Variable speed pump Victaulic 1 male in/1-1/4 1 female 1 female male out 25 25 25 in/32 out Colour code: RAL 7035 In accordance with standard EN14511-3:2013 Not in accordance with standard EN14511-3:2013.These performances do not take into account the correction for the proportionnal heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. In accordance with standard EN14825:2013, average climate Heating mode conditions: water heat exchanger water entering/leaving temperature 40°C/45°C, outside air temperature 7°C db/6°C wb, evaporator fooling factor 0 m².K/W Heating mode conditions: water heat exchanger water entering/leaving temperature 30°C/35°C, outside air temperature 7°C db/6°C wb, evaporator fooling factor 0 m².K/W Heating mode conditions: water heat exchanger water entering/leaving temperature 47°C/55°C, outside air temperature 7°C db/6°C wb, evaporator fooling factor 0 m².K/W Heating mode conditions: water heat exchanger water entering/leaving temperature 55°C/65°C, outside air temperature 7°C db/6°C wb, evaporator fooling factor 0 m².K/W Weight shown is a guideline only. Please refer to the unit nameplate In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). Eurovent certified data A R R I E R 2 0 1 6 / 2 0 1 7 397 AIR TREATMENT Capacity control Minimum capacity Condenser Water volume Max. water-side operating pressure with and without hydronic module Fan Total air flow (high speed) Speed Evaporator Pump Water connections with/without hydronic module kW/kW % kW CONTROLS Standard unit H1 Nominal capacity Full load performances * H1 COP H1 Eurovent class heating H2 Nominal capacity H2 COP H2 Eurovent class heating H3 Nominal capacity H3 COP H4 Nominal capacity H4 COP Full load performances** H1 Gross nominal capacity H1 Gross COP H2 Gross nominal capacity H2 Gross COP H3 Gross nominal capacity H3 COP H4 Gross nominal capacity H4 COP Seasonal efficiency*** H3 SCOP H3 Ƞs heat H3 Prated H3 Energy Class H2 SCOP H2 Ƞs heat H2 Prated H2 Energy Class Operating weight (1) Standard unit (without hydronic kit) Standard unit (plus hydronic module option) Sound levels Sound power level (2) Sound pressure level at 10 m (3) Dimensions Length Depth Height Compressor Refrigerant Charge HEATING Heating