AHI Carrier Catalog | Page 388

Type key Indoor unit (comfort module) 80HMA M Product range 03 03 - 06 - 09 - Back-up electric heater size in kW 00 - For boiler back-up single-phase model (230V 1Ph+N) three-phase model (400V 3Ph+N) Unit description HEATING Part number 80HMA-M00 Indoor unit, reversible, 1 zone, for boiler back-up 80HMA-M03 Indoor unit, reversible, 1 zone, 3 kW 1-ph electric heater back up 80HMA-M06 Indoor unit, reversible, 1 zone, 6 kW 1-ph electric heater back up 80HMA-T06 Indoor unit, reversible, 1 zone, 6 kW 3-ph electric heater back up 80HMA-T09 Indoor unit, reversible, 1 zone, 9 kW 3-ph electric heater back up Accessories Part No. Description Advantages Use 80HMA 33AW-CB02 Communication kit To be installed in 30AWH 30AW----H-- 33AW-CS3 Additional user interface Monitors two independent comfort zones or used together with comfort module interface 80HMA, 80HMA9001, 80HMA-9002 33AW-RAS02 Remote outdoor sensor Positioned in the right place, the OAT sensor maximises comfort compared to using the condensing unit OAT sensor 80HMA 60STS020E03 Domestic hot water tank, 1 coil - 200 l Storage, 200 l of domestic hot water 80HMA 60STS030E03 Domestic hot water tank, 1 coil - 300 l Storage, 300 l of domestic hot water 80HMA 60STD020E03 Domestic hot water tank, 2 coils - 200 l Storage, 200 l of domestic hot water with thermal solar panel connection 80HMA 60STD030E03 Domestic hot water tank, 2 coils - 300 l Storage, 300 l of domestic hot water with thermal solar panel connection 80HMA 80AW9023 Domestic hot-water three-way valve and actuator Necessary to connect domestic hot water tank 80HMA, 60ST, 80HMA-9002 80AW9024 Thermal cut-out, floor heating Stops circulating pump when supply temperature is too high 80HMA, 80HMA9001, 80HMA-9002 80AW9026 Piping kit to install domestic hot-water valve and actuator (80AW9023) inside the unit Specific DHW piping kit for the installation, used together with 80HMA-9001 30HMA-9001 80AW9027 Cover panel to install two-zone kit (80HMA-9001) detached from comfort module Hides piping and connections, if two-zone kit is installed remotely from the main comfort module 80HMA-9001 80AW9028 Kit to add three-way valve and actuator in second zone Necessary to include domestic hot-water three-way valve in second zone kit 80HMA-9001 80HMA-9001 Two-zone kit Allows independent control of two comfort zones 80HMA 80HMA-9002 Pool kit Control box with all necessary sensors required to control three-way valve to divert flow 80HMA 80HMA-9003 Pump kit Necessary when available heat pump pressure is too low for the installation 80HMA 80HMA-9004 BPHE kit (for heat pumps up to 8 kW) Separate heat pump loop (with glycol) from indoor loop; includes BPHE and variable speed circulator 80HMA 80HMA-9005 BPHE kit (for heat pumps up to 16 kW) Separate heat pump loop (with glycol) from indoor loop; includes BPHE and variable speed circulator 80HMA 388 C A R R I E R 2 0 1 6 / 2 0 1 7