AHI Carrier Catalog | Page 387

COMFORT MODULE RANGE FOR MONOBLOC HEAT PUMPS  80HMA Physical data Indoor unit (comfort module) 80HMA-M00 80HMA-M03 80HMA-M06 80HMA-T06 80HMA-T09 1 1 1 1 1 0 3 6 6 9 Number of auxiliary heating steps 1 (external boiler) 1 3 3 3 Connection of back-up boiler Yes No No No No Number of comfort zones kW Electric booster element Dimensions, H x L x D mm 800 x 450 x 320 800 x 450 x 320 800 x 450 x 320 800 x 450 x 320 800 x 450 x 320 Operating weight kg 34 35 35 35 35 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 C6 C20 C32 C16 C20 Recommended circuit breaker size Combination table, indoor and outdoor units Outdoor unit (heat pump) Indoor unit (comfort module) Nominal capacity 4 kW 80HMA-M00 Reversible, 1 zone, maximum heating capacity 20 kW for boiler back-up application 30AWH06HC Nominal capacity 6 kW 80HMA-M03 Reversible, 1 zone, maximum heating capacity 20 kW with 3 kW 1-phase electrical heater booster 30AWH08HC Nominal capacity 8 kW 80HMA-M06 Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 1-phase electrical heater booster 30AWH12HC Nominal capacity 12 kW 80HMA-T06 Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 3-phase electrical heater booster 30AWH12HC9 Nominal capacity 12 kW 80HMA-T06 Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 3-phase electrical heater booster 30AWH15HC Nominal capacity 15 kW 80HMA-T09 Reversible, 1 zone, maximum heating capacity 20 kW with 9 kW 3-phase electrical heater booster 30AWH15HC9 Nominal capacity 15 kW 80HMA-T09 Reversible, 1 zone, maximum heating capacity 20 kW with 9 kW 3-phase electrical heater booster HEATING 30AWH04HC Note: All 30AWH sizes are compatible with the 80HMA comfort module range. Comfort module controls can also manage up to eight 30AWH units. A parallel hydronic coupling of the unit to a tank is necessary (field supply). 30RQ 017 to 021 and 61AF 014 to 019 units are also compatible, but the water volume of this installation must be checked by a professional and comply with the heat pump size minimum requirements. Depending on the terminal unit type installed with the Carrier system a buffer tank may have to be added. M00 M03 M06 T06 T09 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 Voltage range V 207-253 207-253 207-253 360-400 360-400 Max. power consumption, board and auxiliary devices kW Board and auxiliary circuit breaker protection (not included) kW Electric heater power consumption Electric heater circuit breaker protection (not included) 1.15 1.15 1.15 1.15 1.15 C6 C6 C6 C6 C6 0 3 6 6 9 C6 C20 C32 C16 C20 Max. operating current A 5 18 31 14 18 Main power cable size mm2 3G x 2.5 3G x 4 3G x 6 5G x 2.5 5G x 4 Communication cable (FROH2R) mm 2 2 x 0.75 2 x 0.75 2 x 0.75 2 x 0.75 2 x 0.75 User interface (additional or remote) cable (FROH2R) mm2 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 4 x 0.75 Booster heater power supply cable (H05VV-F) mm2 3G x 2.5 3G x 2.5 3G x 2.5 3G x 2.5 3G x 2.5 Booster heater activation cable (FROH2R) mm 2x1 2x1 2x1 2x1 2x1 Domstic hot water sensor cable (FROH2R) mm2 2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5 Remote o utdoor sensor cable (FROH2R) mm 2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5 Note: The heat pump data depends on the heat pump used. C A R R I E R 2 0 1 6 / 2 0 1 7 2 2 CONTROLS Comfort module 80HMA AIR TREATMENT Electrical data 387