REVERSIBLE AIR-TO-WATER HEAT PUMPS 30AWH 004-015
Electrical data
30AW
004
006
008
012
015
012-3Ph
015-3Ph
Power supply
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
400-3-50
400-3-50
Voltage range
V
198-264
198-264
198-264
198-264
198-264
376-424
376-424
Full load current
A
9
11
14.5
20.7
22.6
11.1
11.1
Fuse rating
A
10
16
16
25
25
16
16
Main power cable section
mm2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Type key
30AW
H
006
H
D
9
Power supply: 9 = Three-phase
Liquid chilling packages/
heat pumps
Index
Air-to-water heat pump
HEATING
Unit options
H - With hydronic kit
X - Without hydronic kit
Nominal size
004 - nominal size 4 kW
006 - nominal size 6 kW
008 - nominal size 8 kW
012 - nominal size 12 kW
015 - nominal size 15 kW
H - Standard version
Options
Description
Advantages
Use
30AWH
Additional outdoor sensor
Additional outdoor sensor 33AW-RAS01
Better reading of outdoor air temperature
30AW 004-015
Remote controller
Programmable thermostat
33AW-RC1 remote controller
33AW-CS1 ComfortTM series
programmable thermostat
5 sizes with integrated system control,
expansion vessel and electric booster
heating or boiler backup
Domestic hot water tank 200 or 300 l
On/off, heating/cooling and ECO mode
Extensive control features like weekly
scheduling
Complementary heating system
30AW 004-015
30AW 004-015
Storage, 200 l or 300 l of domestic hot
water
Storage, 200 l or 300 l of domestic hot
water
30AW + 80HMA
80HMA comfort module
Domestic hot water tank
200 or 300 l, 1 coil
Domestic hot water tank
200 or 300 l, 2 coils
Domestic hot water tank 200 or 300 l with
thermal solar panel connection
30AW 004-015
AIR TREATMENT
Options and accessories
30AW + 80HMA
CONTROLS
Note: All 30AWH sizes are compatible with 80HMA comfort module range and domestic hot water tank models.
Please refer to 80HMA documentation to get the option codes and the list of complementary accessories.
Please consider that 80HMA is necessary to manage water sensor and electric heater integrated into DHW tank.
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
379