AHI Carrier Catalog | Page 378

Physical data 30AWH 004 Refrigerant 006 008 012 015 012-3Ph 015-3Ph R410A Circuit charge (1) kg 1.195 1.35 1.81 2.45 3.385 2.45 3.385 CO2 eq. 2.5 2.8 3.8 5.1 7.1 5.1 7.1 Air heat exchangers Copper tubes and aluminium fins Fans Variable speed 3 blades fan Quantity 1 1 1 2 2 2 2 Water heat exchanger (X version) Water pressure drop (C1) kPa 10 8 10 20 28 20 28 Water pressure drop (H1) kPa 17 12 14 25 33 25 33 Water pressure drop (H2) kPa 16 12 14 29 31 29 31 Min. system water content l 14 21 28 42 49 42 49 Max. water-side operating pressure kPa 300 300 300 300 300 300 300 Hydronic module (H version) Pump HEATING Expansion tank volume Variable speed circulator l 2 2 2 3 3 3 3 Available static pressure (C1) kPa 69 72 58 62 37 66 37 Available static pressure (H1) kPa 60 60 56 70 58 70 55 Available static pressure (H2) kPa 62 60 55 72 60 73 58 Min. system water content l 14 21 28 42 49 42 49 Max. water-side operating pressure kPa 300 300 300 300 300 300 300 Diameter inch 1M 1M 1M 1M 1M 1M 1M Outside tube diameter  mm 25.4 M 25.4 M 25.4 M 25.4 M 25.4 M 25.4 M 25.4 M Water connections with or without hydronic module Chassis paint colour Beige C1 Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W H1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H2 Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, (1) Weights are guideline only. Refer to the unit nameplate 378 C A R R I E R 2 0 1 6 / 2 0 1 7