REVERSIBLE AIR-TO-WATER HEAT PUMPS 30AWH 004-015
Physical data
30AWH
004
006
008
012
015
012-3Ph
015-3Ph
Cooling
H version
Full load
performances*
C1
Nominal capacity
kW
3.33
4.73
5.84
10.24
13.04
10.20
13.00
C1
EER
kW/kW
3.02
3.00
2.98
2.96
2.95
3.00
2.91
C1
Eurovent class cooling
B
B
B
B
B
B
B
C2
Nominal capacity
kW
4.93
7.04
7.84
13.54
16.04
13.50
16.00
C2
EER
kW/kW
4.20
3.70
3.99
3.66
3.85
4.15
3.81
C2
Eurovent class cooling
A
B
A
B
A
A
A
ESEER
kW/kW
4.36
4.51
4.15
4.22
4.31
4.4
4.31
H1
Nominal capacity
kW
4.07
5.76
7.16
11.86
14.46
12
15
H1
COP
kW/kW
4.15
4.28
3.97
3.95
4.09
4.3
4.2
H1
Eurovent class cooling
A
A
B
B
A
A
A
H2
Nominal capacity
kW
3.87
5.76
7.36
12.91
13.96
11.20
14.50
H2
COP
kW/kW
3.26
3.05
3.19
3.03
3.23
3.35
3.30
H2
Eurovent class cooling
A
B
B
B
A
A
A
H3
Nominal capacity
kW
4.27
5.43
7.25
10.89
12.36
11.43
12.17
H3
COP
kW/kW
2.92
2.77
2.81
2.79
3.02
3.12
2.98
H3
SCOP
kW/kW
3.53
3.37
2.84
2.95
3.25
3.47
3.33
H3
Ƞs heat
%
138
132
111
115
127
136
130
H3
Prated
kW
3.28
4.22
4.65
8.68
9.05
8.38
9.37
H3
Annual energy
consumption
kWh
1900
2571
3367
6077
5748
4975
5806
H3
Energy efficiency class
A++
A++
A+
A+
A++
A++
A++
dB(A)
64
64
65
68
69
69
69
Length
mm
908
908
908
908
908
908
908
Depth
mm
350
350
350
350
350
350
350
Height
mm
821
821
821
1363
1363
1363
1363
Unit without circulator (X version)
kg
54
58
66
101
109
113
113
Unit with circulator (H version)
kg
57
61
69
104
112
116
116
Seasonal
efficiency*
H version
Full load
performances*
Seasonal
efficiency**
HEATING
Heating
Sound levels standard unit
Sound power level(1) (C1)
Operating weight(3)
Compressors
DC Inverter Twin-Rotary
CONTROLS
*
In accordance with standard EN14511-3:2013
** In accordance with standard EN14825:2013, average climate
C1 Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W
C2 Cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W
H1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb,
H2 Heating mode conditions: Water heat exchanger water entering /leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb,
H3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb,
(1) In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1.
(2) In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
(3) Weights are guideline only. Refer to the unit nameplate
Eurovent certified data
Eurovent certified data
C
A
R
R
I
E
AIR TREATMENT
Dimensions
R
2
0
1
6
/
2
0
1
7
377