AHI Carrier Catalog | Page 377

REVERSIBLE AIR-TO-WATER HEAT PUMPS  30AWH 004-015 Physical data 30AWH 004 006 008 012 015 012-3Ph 015-3Ph Cooling H version Full load performances* C1 Nominal capacity kW 3.33 4.73 5.84 10.24 13.04 10.20 13.00 C1 EER kW/kW 3.02 3.00 2.98 2.96 2.95 3.00 2.91 C1 Eurovent class cooling B B B B B B B C2 Nominal capacity kW 4.93 7.04 7.84 13.54 16.04 13.50 16.00 C2 EER kW/kW 4.20 3.70 3.99 3.66 3.85 4.15 3.81 C2 Eurovent class cooling A B A B A A A ESEER kW/kW 4.36 4.51 4.15 4.22 4.31 4.4 4.31 H1 Nominal capacity kW 4.07 5.76 7.16 11.86 14.46 12 15 H1 COP kW/kW 4.15 4.28 3.97 3.95 4.09 4.3 4.2 H1 Eurovent class cooling A A B B A A A H2 Nominal capacity kW 3.87 5.76 7.36 12.91 13.96 11.20 14.50 H2 COP kW/kW 3.26 3.05 3.19 3.03 3.23 3.35 3.30 H2 Eurovent class cooling A B B B A A A H3 Nominal capacity kW 4.27 5.43 7.25 10.89 12.36 11.43 12.17 H3 COP kW/kW 2.92 2.77 2.81 2.79 3.02 3.12 2.98 H3 SCOP kW/kW 3.53 3.37 2.84 2.95 3.25 3.47 3.33 H3 Ƞs heat % 138 132 111 115 127 136 130 H3 Prated kW 3.28 4.22 4.65 8.68 9.05 8.38 9.37 H3 Annual energy consumption kWh 1900 2571 3367 6077 5748 4975 5806 H3 Energy efficiency class A++ A++ A+ A+ A++ A++ A++ dB(A) 64 64 65 68 69 69 69 Length mm 908 908 908 908 908 908 908 Depth mm 350 350 350 350 350 350 350 Height mm 821 821 821 1363 1363 1363 1363 Unit without circulator (X version) kg 54 58 66 101 109 113 113 Unit with circulator (H version) kg 57 61 69 104 112 116 116 Seasonal efficiency* H version Full load performances* Seasonal efficiency** HEATING Heating Sound levels standard unit Sound power level(1) (C1) Operating weight(3) Compressors DC Inverter Twin-Rotary CONTROLS * In accordance with standard EN14511-3:2013 ** In accordance with standard EN14825:2013, average climate C1 Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W C2 Cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W H1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H2 Heating mode conditions: Water heat exchanger water entering /leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, (1) In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1. (2) In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). (3) Weights are guideline only. Refer to the unit nameplate Eurovent certified data Eurovent certified data C A R R I E AIR TREATMENT Dimensions R 2 0 1 6 / 2 0 1 7 377