AHI Carrier Catalog | Page 365

AIR-TO-WATER HEAT PUMP HEATING SYSTEM  38AW/80AW Type key Outdoor unit 38AW 050 H7 H9 Three-phase 3 x 400 V/50 Hz + neutral H7 Single-phase 1 x 230 V/50 Hz Air-cooled condensing unit 050 – Outdoor unit with nominal size 5.0 kW 065 – Outdoor unit with nominal size 6.5 kW 090 – Outdoor unit with nominal size 9.0 kW 115 – Outdoor unit with nominal size 11.5 kW 120 – Outdoor unit with nominal size 12.0 kW 150 – Outdoor unit with nominal size 15.0 kW Air-to water unit Indoor unit 80AW X 065 M 6 - - B Revision status Product range HEATING Electric heater capacity, kW 0 = boiler backup X – Heating and cooling H – Heating only Power supply M = single-phase T = three-phase + neutral Heating capacity, kW Combination table, outdoor and indoor units Indoor unit 38AW 050H7 38AW 065H7 80AWX 065M0 Reversible, 1 zone, max. heating capacity 6.5 kW for boiler backup 80AWX 065M3 Reversible, 1 zone, max. heating capacity 6.5 kW with 3 kW 1-ph electric heater backup 80AWX 065M6 Reversible, 1 zone, max. heating capacity 6.5 kW with 6 kW 1-ph electric heater backup 80AWX 065T6 Reversible, 1 zone, max. heating capacity 6.5 kW with 6 kW 3-ph electric heater backup 80AWH 065M0 Heating only, 1 zone, max. heating capacity 6.5 kW for boiler backup 80AWH 065M3 Heating only, 1 zone, max. heating capacity 6.5 kW with 3 kW 1-ph electric heater backup 80AWH 065M6 Heating only, 1 zone, max. heating capacity 6.5 kW with 6 kW 1-ph electric heater backup 80AWH 065T6 Heating only, 1 zone, max. heating capacity 6.5 kW with 6 kW 3-ph electric heater backup 80AWX 115M0 Reversible, 1 zone, max. heating capacity 11.5 kW for boiler backup 80AWX 115M3 Reversible, 1 zone, max. heating capacity 11.5 kW with 3 kW 1-ph electric heater backup 80AWX 115M6 Reversible, 1 zone, max. heating capacity 11.5 kW with 6 kW 1-ph electric heater backup 80AWX 115T6 Reversible, 1 zone, max. heating capacity 11.5 kW with 6 kW 3-ph electric heater backup 80AWX 115T9 Reversible, 1 zone, max. heating capacity 11.5 kW with 9 kW 3-ph electric heater backup 80AWH 115M0 Heating only, 1 zone, max. heating capacity 11.5 kW for boiler backup 80AWH 115M3 Heating only, 1 zone, max. heating capacity 11.5 kW with 3 kW 1-ph electric heater backup 80AWH 115M6 Heating only, 1 zone, max. heating capacity 11.5 kW with 6 kW 1-ph electric heater backup 80AWH 115T6 Heating only, 1 zone, max. heating capacity 11.5 kW with 6 kW 3-ph electric heater backup 80AWH 115T9 Heating only, 1 zone, max. heating capacity 11.5 kW with 9 kW 3-ph electric heater backup 80AWX 150M0 Reversible, 1 zone, max. heating capacity 15 kW for boiler backup 80AWX 150T6 Reversible, 1 zone, max. heating capacity 15 kW with 6 kW 3-ph electric heater backup 80AWX 150T9 Reversible, 1 zone, max. heating capacity 15 kW with 9 kW 3-ph electric heater backup 80AWH 150M0 Heating only, 1 zone, max. heating capacity 15 kW for boiler backup 80AWH 150T6 Heating only, 1 zone, max. heating capacity 15 kW with 6 kW 3-ph electric heater backup 80AWH 150T9 Heating only, 1 zone, max. heating capacity 15 kW with 9 kW 3-ph electric heater backup 38AW 090H7 38AW 115H7 9 kW nominal capacity 11.5 kW nominal capacity 38AW 120H9 38AW 150H9 C A R R 12 kW nominal capacity 15 kW nominal capacity I E R 2 0 1 6 / 2 0 1 7 CONTROLS 5 kW nominal capacity 6.5 kW nominal capacity AIR TREATMENT Outdoor unit 365