AIR-TO-WATER HEAT PUMP HEATING SYSTEM 38AW/80AW
Type key
Outdoor unit
38AW 050 H7
H9 Three-phase 3 x 400 V/50 Hz + neutral
H7 Single-phase 1 x 230 V/50 Hz
Air-cooled condensing unit
050 – Outdoor unit with nominal size 5.0 kW
065 – Outdoor unit with nominal size 6.5 kW
090 – Outdoor unit with nominal size 9.0 kW
115 – Outdoor unit with nominal size 11.5 kW
120 – Outdoor unit with nominal size 12.0 kW
150 – Outdoor unit with nominal size 15.0 kW
Air-to water unit
Indoor unit
80AW X 065 M 6 - - B
Revision status
Product range
HEATING
Electric heater capacity, kW
0 = boiler backup
X – Heating and cooling
H – Heating only
Power supply
M = single-phase
T = three-phase + neutral
Heating capacity, kW
Combination table, outdoor and indoor units
Indoor unit
38AW 050H7
38AW 065H7
80AWX 065M0
Reversible, 1 zone, max. heating capacity 6.5 kW for boiler backup
80AWX 065M3
Reversible, 1 zone, max. heating capacity 6.5 kW with 3 kW 1-ph electric heater backup
80AWX 065M6
Reversible, 1 zone, max. heating capacity 6.5 kW with 6 kW 1-ph electric heater backup
80AWX 065T6
Reversible, 1 zone, max. heating capacity 6.5 kW with 6 kW 3-ph electric heater backup
80AWH 065M0
Heating only, 1 zone, max. heating capacity 6.5 kW for boiler backup
80AWH 065M3
Heating only, 1 zone, max. heating capacity 6.5 kW with 3 kW 1-ph electric heater backup
80AWH 065M6
Heating only, 1 zone, max. heating capacity 6.5 kW with 6 kW 1-ph electric heater backup
80AWH 065T6
Heating only, 1 zone, max. heating capacity 6.5 kW with 6 kW 3-ph electric heater backup
80AWX 115M0
Reversible, 1 zone, max. heating capacity 11.5 kW for boiler backup
80AWX 115M3
Reversible, 1 zone, max. heating capacity 11.5 kW with 3 kW 1-ph electric heater backup
80AWX 115M6
Reversible, 1 zone, max. heating capacity 11.5 kW with 6 kW 1-ph electric heater backup
80AWX 115T6
Reversible, 1 zone, max. heating capacity 11.5 kW with 6 kW 3-ph electric heater backup
80AWX 115T9
Reversible, 1 zone, max. heating capacity 11.5 kW with 9 kW 3-ph electric heater backup
80AWH 115M0
Heating only, 1 zone, max. heating capacity 11.5 kW for boiler backup
80AWH 115M3
Heating only, 1 zone, max. heating capacity 11.5 kW with 3 kW 1-ph electric heater backup
80AWH 115M6
Heating only, 1 zone, max. heating capacity 11.5 kW with 6 kW 1-ph electric heater backup
80AWH 115T6
Heating only, 1 zone, max. heating capacity 11.5 kW with 6 kW 3-ph electric heater backup
80AWH 115T9
Heating only, 1 zone, max. heating capacity 11.5 kW with 9 kW 3-ph electric heater backup
80AWX 150M0
Reversible, 1 zone, max. heating capacity 15 kW for boiler backup
80AWX 150T6
Reversible, 1 zone, max. heating capacity 15 kW with 6 kW 3-ph electric heater backup
80AWX 150T9
Reversible, 1 zone, max. heating capacity 15 kW with 9 kW 3-ph electric heater backup
80AWH 150M0
Heating only, 1 zone, max. heating capacity 15 kW for boiler backup
80AWH 150T6
Heating only, 1 zone, max. heating capacity 15 kW with 6 kW 3-ph electric heater backup
80AWH 150T9
Heating only, 1 zone, max. heating capacity 15 kW with 9 kW 3-ph electric heater backup
38AW 090H7
38AW 115H7
9 kW nominal capacity
11.5 kW nominal capacity
38AW 120H9
38AW 150H9
C
A
R
R
12 kW nominal capacity
15 kW nominal capacity
I
E
R
2
0
1
6
/
2
0
1
7
CONTROLS
5 kW nominal capacity
6.5 kW nominal capacity
AIR TREATMENT
Outdoor unit