Physical data
Indoor unit (Comfort module)
80AW 115
M0
Outdoor units
M3
M6
T6
T9
38AW 090H7/38AW 115H7
Power supply
V-ph-Hz
230-1-50
230-1-50
230-1-50
400-3N-50
400-3N-50
Voltage range
V-ph-Hz
207-253
207-253
207-253
360-440
360-440
Power input
kW
-
3
6
6
9
L1
A
-
13.0
26
8.7
13.0
L2
A
-
-
-
8.7
13.0
L3
A
-
-
-
8.7
13.0
N
A
-
13.0
26
-
-
Power factor
%
1
1
1
1
1
Indoor unit power supply and
communication cable - H07 RN-F
mm2
2G x 1
2G x 1
2G x 1
2G x 1
2G x 1
Backup heater power supply
cable - H07 RN-F
mm2
-
3G x 4
3G x 6
5G x 2.5
5G x 4
User interface cable (additional
or remote) - FROH2R
mm2
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
Booster heater power supply
cable - H05VV-F
mm2
3G x 2.5
3G x 2.5
3G x 2.5
3G x 2.5
3G x 2.5
DHW booster heater activation
cable - FROH2R
mm2
2x1
2x1
2x1
2x1
2x1
DHW hot water sensor
cable - FROH2R
mm2
2 x 0.5
2 x 0.5
2 x 0.5
2 x 0.5
2 x 0.5
Remote outdoor sensor
cable - FROH2R
mm2
2 x 0.5
2 x 0.5
2 x 0.5
2 x 0.5
2 x 0.5
HEATING
Operating current
Indoor unit (Comfort module)
80AW 150
M0
Outdoor units
T6
T9
38AW 120H9/38AW 150H9
V-ph-Hz
230-1-50
400-3N-50
400-3N-50
Voltage range
V-ph-Hz
207-253
376-424
376-424
Power input
kW
-
6
9
L1
A
-
8.7
13.0
L2
A
-
8.7
13.0
L3
A
-
8.7
13.0
N
A
-
-
-
Power factor
%
1
1
1
Indoor unit power supply and
communication cable - H07 RN-F
mm
2G x 1
2G x 1
2G x 1
Backup heater power supply
cable - H07 RN-F
mm2
-
5G x 2.5
5G x 4
User interface cable (additional
or remote) - FROH2R
mm2
4 x 0.75
4 x 0.75
4 x 0.75
Booster heater power supply
cable - H05VV-F
mm2
3G x 2.5
3G x 2.5
3G x 2.5
DHW booster heater activation
cable - FROH2R
mm2
2x1
2x1
2x1
DHW hot water sensor
cable - FROH2R
mm2
2 x 0.5
2 x 0.5
2 x 0.5
Remote outdoor sensor
cable - FROH2R
mm2
2 x 0.5
2 x 0.5
2 x 0.5
Power supply
Operating current
364
2
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7