AHI Carrier Catalog | Page 359

AIR-TO-WATER HEAT PUMP HEATING SYSTEM  38AW/80AW Physical data 38AW/80AW Outdoor unit (heat pump) Indoor unit (comfort module) 38AW 38AW 38AW 38AW 38AW 38AW 050H7 065H7 090H7 115H7 120H9 150H9 80AWH 80AWH 80AWH 80AWH 80AWH 80AWH 065 065 115 115 150 150 3.57 4.73 5.95 6.80 10.30 12.60 Cooling (80AWX only) Full load performances* C1 Nominal capacity kW kW/kW C1 EER C1 Eurovent class cooling C2 Nominal capacity kW C2 EER kW/kW C2 Eurovent class cooling Seasonal efficiency* ESEER kW/kW 2.60 2.60 3.07 2.88 3.41 3.17 D D B C A A 5.10 6.55 7.88 9.00 13.50 15.79 3.40 3.40 4.05 3.80 4.74 4.24 D D A A A A 3.71 3.71 4.45 4.37 4.56 4.79 Seasonal efficiency** (80AWX only) Seasonal efficiency** (80AWH only) H1 Nominal capacity kW 5.01 6.55 9.27 11.50 12.00 15.01 H1 COP kW/kW 4.15 4.15 4.48 4.10 4.65 4.30 H1 Eurovent class cooling A A A A A A H2 Nominal capacity kW 4.37 5.70 8.70 11.30 11.20 14.02 H2 COP kW/kW 3.41 3.34 3.45 3.32 3.70 3.40 H2 Eurov ent class cooling A A A A A A H3 Nominal capacity kW 4.25 5.52 7.88 10.95 11.48 11.91 H3 COP kW/kW 2.65 2.86 2.90 2.79 3.12 3.10 H3 SCOP kW/kW 3.00 2.98 2.99 2.94 3.45 3.29 H3 Ƞs heat % 117 116 117 115 135 128 H3 Prated kW 1.90 2.16 7.60 8.75 8.37 9.38 H3 Annual energy consumption kWh 1303 1494 5245 6143 5004 5897 A+ A+ A+ A+ A++ A++ kW/kW 2.81 2.81 2.94 2.90 3.39 3.24 H3 Energy efficiency class H3 SCOP H3 Ƞs heat % 110 110 115 113 133 127 H3 Prated kW 1.90 2.16 7.60 8.75 8.37 9.38 H3 Annual energy consumption kWh 1303 1494 5245 6143 5004 5897 H3 Energy efficiency class A+ A+ A+ A+ A++ A++ AIR TREATMENT Full load performances* HEATING Heating (80AWX and 80AWH) CONTROLS * In accordance with standard EN14511-3:2013 ** In accordance with standard EN14825:2013, average climate C1 Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W C2 Cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0 m² K/W H1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H2 Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, H3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, (1) In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1. (2) In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). (3) Weights are guideline only. Refer to the unit nameplate. Eurovent certified data Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 359