AHI Carrier Catalog | Page 335

Standard Option 400 V - 3 phase - 50Hz (Voltage control within ±10%, frequency control within ±5%) Contact the Carrier representative One section Multi-shipment Refrigerant temperature Chilled water freeze protection Chilled water flow switch Cooling water temperature HT generator temperature HT generator pressure HT generator solution level Crystallisation protection Motor protection Cooling water flow switch Capacity control Digital PID control by chilled-water temperature Inverter control of #1 absorbent pump Parts Selected by Carrier No option Painting Munsell 5Y-7/1 No option Indication lights Operation Stop Alarm No option No option No option Display LED No option External terminals (volt-free normally open contact) Operation indication Stop indication Alarm indication Feedback indication Cooling mode indication No option Structure Parts Indoor type Selected by Carrier No option No option Wire: 600 V polyvinyl grade (chloride-insulated wires) Pipe: Plicatube (flexible metal conduits) No option No option Indoor 5 °C through 40 °C Relative humidity: Max. 90 % at 45 °C No option No option No option Be sure the following are not present: - Corrosive gas - Explosive gas - Poisonous gas No option Electricity Power supply Shipment Control Safety functions HEATING HEATING Control panel Electrical wiring and piping Insulation condition Place Ambient temperature Ambient humidity Atmosphere Features and advantages ■■ They reduce the contribution to global warming and minimise the global impact by greatly reducing electricity consumption and production of greenhouse gases. ■■ The solution inhibitor has no impact on the environment. ■■ An absorption chiller does not utilise mechanical moving parts, and this leads to quiet, vibration-free operation. ■■ The use of high-efficiency heat transfer surfaces has reduced the space required for installation of the absorption chiller, resulting in a smaller footprint. CONTROLS ■■ The Carrier 16TJ single-effect absorption chillers are designed for cooling applications where low-pressure steam is available as waste heat. ■■ They can tie into district steam systems. ■■ Carrier absorption chillers allow diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power input. ■■ They allow smaller emergency generators compared to an electrical driven chiller. ■■ The units are ozone-safe and CFC-free. Cooling requirements are met without chlorine-based refrigerants. AIR TREATMENT Item COOLING SINGLE-EFFECT STEAM-FIRED ABSORPTION CHILLERS 16TJ 11-53 C A R R I E R 2 0 1 6 / 2 0 1 7 335