AHI Carrier Catalog | Page 292

Designation (Example) COOLING 09PE DLN 9124-2 SHI 690A Rotation speed Induced draught Position (H = Horizontal, V = Vertical) Coil type (S = Single, Z = Drainable) Number of fan lines (1 or 2) Number of coil rows Number of fans Impeller diameter (8 = 800, 9 = 900 mm) Module size (S = Short, M = Medium, L = Long) D = Drycooler Options for each application Protection adapted for the environment Options Description/Advantages Pre-coated aluminium fins Improves the resistance of the fins to corrosion. For low corrosion environments. • High efficiency coating on the finned bundle: ALUCOAT®507 or HERESITE Improves the resistance of the fins to corrosion. For corrosive environments. • Stainless steel tube bundle For corrosive fluids. • Corrosiveness resistance category C5M Casing and fan motor assemblies for corrosive environments. • For explosive atmospheres. • ATEX II 2G/3G Terminal box Protection cabinet Control cabinet with DRY-PIC Control cabinet with stages on Quick, simple installation terminals For stopping individual motors. Companion flanges In stainless steel, with gaskets and bolts. Fins protective screen Optimised, secure transport Vertical position Skid for transport by container Free cooling application Free cooling valve kit 292 • • • • • • To ensure a good flow of air depending on how the units are installed: against a wall, side by side, etc. Protection against hail, impacts, etc. For forced draught, vertical units. • • For narrow terraces. • Secure transport and easy loading/unloading. • • Stacking of 2 identical devices Optimisation of electrical EC motor consumption and sound (with electronic switching) levels Application for water Drainable coil without glycol Application with adiabatic cooling Connection to the terminals of each motor on the front panel of unit. Protected by a thermal-magnetic circuit breaker on each motor. Protection for motors and stage regulation provided by an electronic board according to temperature or pressure. Motor protection and stages controlled by the customer control. Maintenance switch Raised feet Installation surface constraints DRYCOOLER ADIABATIC COOLER (water misting into the air flow) Variable speed control from 0 to 100% using a 0/10V signal. With the control cabinet via electronic board option, the device is self-regulating • Device located on a slope to prevent frost - drainage by gravity Valves with motor and sensor, controlled by the electronic board. Controlled according to the operation of the drycooler or chiller. Size of the unit reduced by cooling of the ambient air. Operates completely safely due to the antibacterial treatment applied to the water. C A R R I E R 2 0 1 6 • • • / 2 0 1 7