Designation (Example)
COOLING
09PE DLN 9124-2 SHI 690A
Rotation speed
Induced draught
Position (H = Horizontal, V = Vertical)
Coil type (S = Single, Z = Drainable)
Number of fan lines (1 or 2)
Number of coil rows
Number of fans
Impeller diameter (8 = 800, 9 = 900 mm)
Module size (S = Short, M = Medium, L = Long)
D = Drycooler
Options for each application
Protection adapted
for the environment
Options
Description/Advantages
Pre-coated aluminium fins
Improves the resistance of the fins to corrosion.
For low corrosion environments.
•
High efficiency coating on the finned
bundle:
ALUCOAT®507 or HERESITE
Improves the resistance of the fins to corrosion.
For corrosive environments.
•
Stainless steel tube bundle
For corrosive fluids.
•
Corrosiveness resistance
category C5M
Casing and fan motor assemblies for corrosive
environments.
•
For explosive atmospheres.
•
ATEX II 2G/3G
Terminal box
Protection cabinet
Control cabinet with
DRY-PIC
Control cabinet with stages on
Quick, simple installation terminals
For stopping individual motors.
Companion flanges
In stainless steel, with gaskets and bolts.
Fins protective screen
Optimised, secure
transport
Vertical position
Skid for transport by container
Free cooling application Free cooling valve kit
292
•
•
•
•
•
•
To ensure a good flow of air depending on how the units
are installed: against a wall, side by side, etc.
Protection against hail, impacts, etc.
For forced draught, vertical units.
•
•
For narrow terraces.
•
Secure transport and easy loading/unloading.
•
•
Stacking of 2 identical devices
Optimisation
of electrical
EC motor
consumption and sound (with electronic switching)
levels
Application for water
Drainable coil
without glycol
Application with
adiabatic cooling
Connection to the terminals of each motor on the front
panel of unit.
Protected by a thermal-magnetic circuit breaker on each
motor.
Protection for motors and stage regulation provided by an
electronic board according to temperature or pressure.
Motor protection and stages controlled by the customer
control.
Maintenance switch
Raised feet
Installation surface
constraints
DRYCOOLER
ADIABATIC COOLER (water misting
into the air flow)
Variable speed control from 0 to 100% using a 0/10V
signal. With the control cabinet via electronic board option,
the device is self-regulating
•
Device located on a slope to prevent frost - drainage by
gravity
Valves with motor and sensor, controlled by the electronic
board. Controlled according to the operation of the
drycooler or chiller.
Size of the unit reduced by cooling of the ambient
air. Operates completely safely due to the antibacterial
treatment applied to the water.