AHI Carrier Catalog | Page 291

FLUIDE COOLERS 09PE Range 09PE is a large modular range, which offers: ■■ 3 casing lengths (S, M or L module), allowing either the dimensions, the capacity or the power consumption to be optimised, ■■ A range of sizes, from 1 to 14 fans, ■■ 2 impeller diameters, 800 or 910 mm, ■■ Several rotation speeds, from 300 to 1 000 rpm, ■■ Configuration: horizontal or vertical unit, ■■ Various combinations of these elements, as well as the choice of a number of options, allow us to provide devices that are adapted to a lange range of applications and environments. AC MOTORS COOLING Electrical data EC MOTOR 900 690 890 680 Wiring Δ Y Δ Y 1000 I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) 9010-1 5.3 2.65 3 1.84 3.9 2.13 2.3 1.33 4.4 2.98 9020-1 10.6 5.3 6 3.68 7.8 4.26 4.6 2.66 8.8 5.96 9030-1 15.9 7.95 9 5.52 11.7 6.39 6.9 3.99 13.2 8.94 9040-1 21.2 10.6 12 7.36 15.6 8.52 9.2 5.32 17.6 11.92 9050-1 26.5 13.25 15 9.2 19.5 10.65 11.5 6.65 22 14.9 9040-2 21.2 10.6 12 7.36 15.6 8.52 9.2 5.32 17.6 11.92 9060-2 31.8 15.9 18 11.04 23.4 12.78 13.8 7.98 26.4 17.88 9080-2 42.4 21.2 24 14.72 31.2 17.04 18.4 10.64 35.2 23.84 9100-2 53 26.5 30 18.4 39 21.3 23 13.3 44 29.8 9120-2 63.6 31.8 36 22.08 46.8 25.56 27.6 15.96 52.8 35.76 9140-2 74.2 37.1 42 25.76 54.6 29.82 32.2 18.62 61.6 41.72 H EATING HEATING Speed I  : maximum input current P : maximum power input The currents and power actually absorbed depend on the operation point and will be indicated in detail when the unit is selected. Speed 900 700 690 560 425 300 Wiring Δ Y Δ Y Δ Y 8010-1 510 740 I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) I (A) P(kW) 3.65 1.98 1.43 0.895 1.05 0.56 0.194 0.35 0.075 0.49 0.298 1.4 0.918 2.4 2.1 8020-1 7.3 3.96 4.8 2.86 4.2 1.79 1.12 0.84 0.388 0.7 0.15 0.98 0.596 2.8 1.836 8030-1 10.95 5.94 7.2 4.29 6.3 2.685 3.15 1.68 1.26 0.582 1.05 0.225 1.47 0.894 4.2 2.754 8040-1 14.6 9.6 5.72 8.4 3.58 2.24 1.68 0.776 1.4 0.3 1.192 5.6 3.672 4.59 7.92 12 2.1 0.42 4.2 8050-1 18.25 9.9 7.15 10.5 4.475 5.25 2.8 2.1 0.97 0.375 2.45 1.49 8060-1 21.9 11.88 14.4 8.58 12.6 5.37 6.3 3.36 2.52 1.164 2.1 0.45 2.94 1.788 8.4 5.508 8040-2 14.6 7.92 5.72 8.4 3.58 4.2 2.24 1.68 0.776 1.4 0.3 1.96 1.192 5.6 3.672 9.6 1.75 1.96 7 8060-2 21.9 11.88 14.4 8.58 12.6 5.37 6.3 3.36 2.52 1.164 2.1 0.45 2.94 1.788 8.4 5.508 8080-2 29.2 15.84 19.2 11.44 16.8 7.16 8.4 4.48 3.36 1.552 2.8 0.6 3.92 2.384 11.2 7.344 8100-2 36.5 19.8 14.3 8.95 10.5 5.6 4.2 1.94 0.75 4.9 2.98 9.18 8120-2 43.8 23.76 28.8 17.16 25.2 10.74 12.6 6.72 5.04 2.328 4.2 0.9 5.88 3.576 16.8 11.016 8140-2 51.1 27.72 33.6 20.02 29.4 12.53 14.7 7.84 5.88 2.716 4.9 1.05 6.86 4.172 19.6 12.852 24 21 3.5 14 I  : maximum input current P : maximum power input The currents and power actually absorbed depend on the operation point and will be indicated in detail when the unit is selected. C A R R I E R 2 0 1 6 / 2 0 1 7 291 AIR TREATMENT EC MOTOR CONTROLS AC MOTORS